Hanna Instruments HI 98143 Instruction Manual
Instruction ManualHI 98143pH & EC Transmitterwith Isolated OutputWARRANTYThese instruments are warranted for two years against defects inworkmanship and materials when used for its intended purpose and main-tained according to instructions. Electrodes and probes are warrantedfor a period of six months. This warranty is limited to repair or re-placement free of charge.Damages due to accident, misuse, tampering or lack of prescribed main-tenance are not covered.If service is required, contact the dealer from whom you purchased theinstrument. If under warranty, report the model number, date of purchase,serial number and the nature of the failure. If the repair is not covered bythe warranty, you will be notified of the charges incurred. If the instrumentis to be returned to Hanna Instruments, first obtain a Returned GoodsAuthorization Number from the Customer Service department and thensend it with shipment costs prepaid. When shipping any instrument, makesure it is properly packaged for complete protection.All rights are reserved. Reproduction in whole or in part is prohibitedwithout the written consent of the copyright owner.Dear Customer,Thank you for choosing a Hanna product.This manual will provide you with the necessary informationfor the correct operation of the meter. Please read it carefullybefore using the meter.If you need additional technical information, do not hesitateto e-mail us at tech@hannainst.com.These instruments are in compliance with the directives.Remove the instrument from the packing material and exam-ine it carefully. If any damage has occurred during shipment,immediately notify your Dealer or the nearest Hanna CustomerService Center.Each instrument is supplied complete with instructions.Note: Conserve all packing material until the instrument hasbeen observed to function correctly. Any defective itemmust be returned in its original packing.PRELIMINARY EXAMINATIONHI 98143 is a panel mounted pH and EC transmitter speciallydesigned to accept signals directly from a pH electrode andconductivity probe at the same time.Direct connections of the probes to the transmitter assures apositive electrical connection with no signal loss.Four models are available, transmitting at 0-1 V, 0-4 V or 4-20 mA signal. The output signals are prooprtional to theinput signals, but independent of changes in load or cablecapacitance.Conductivity readings are compensated for temperature changes.These transmitters can be connected to any pH or conductivitycontroller, recorder, computer or any data monitoring devicethat accepts 0 to 1 V, 0 to 4 V or 4 to 20 mA input.The HI 98143-22 model has been specifically designed to beused with the HI 8000 fertigation controllers.GENERAL DESCRIPTIONFUNCTIONAL DESCRIPTION1. pH offset calibration trimmer2. pH slope calibration trimmer3. BNC connector for pH electrode4. pH electrode (not included)5. Potential matching pin (not included)6. Conductivity probe (not included)7. 12-24 Vdc power adapter (not included)8. pH output terminals9. EC output terminals10. Power supply terminals11. EC slope calibration trimmer12. EC offset calibration trimmerSPECIFICATIONSRangepH 0 to 14 pHEC 0 to 10 mS/cmAccuracy(@ 25°C/77°F)pH ±0.5% f.s.EC ±2% f.s.Typical EMC DeviationpH ±2% f.s.EC ±2% f.sIsolated Output (pH and EC)HI 98143-01 0-1 VHI 98143-04 0-4 VHI 98143-20 4-20 mA (passive)HI 98143-22 4-20 mA (active)Calibration Manual, 2 point, through trimmerspH offset and slope trimmersEC 0 and 5 mS/cm trimmersTemperature Compensation (EC only)Automatic from 0 to 60°C with ß=2%/ºCpH Electrode HI 1001 pH electrode (suggested) andHI 1283 matching pin (not included)EC Probe HI 3001(not included) with cell constant 2.1Casing IP54Power Supply 12-24 VdcEnvironment 0 to 50°C (32 to 122°F); RH max 95%Dimensions 160 x 105 x 31mm (6.3 x 4.1 x 1.2”)Weight 280 g (9.9 oz.)HI 98143-01HI 98143-04HI 98143-20HI 98143-220 to 14 pH = 0 to 1 Vdc0 to 10 mS = 0 to 1 Vdc0 to 14 pH = 0 to 4 Vdc0 to 10 mS = 0 to 4 Vdc0 to 14 pH = 4 to 20 mA0 to 10 mS = 4 to 20 mA0 to 14 pH = 4 to 20 mA0 to 10 mS = 4 to 20 mAw w w . h a n n a i n s t . c o mHanna Instruments reserves the right to modify the design, constructionand appearance of its products without advance notice.ACCESSORIESHI 1001 “flow-thru”, double junction pH electrode withBNC connector and 3 m (10’)HI 1283 Stainless steel grounding probe with 2 m(6.6’) cableHI 3001 “flow-thru”, 4 platinum ring EC probe withbuilt-in temperature sensor & 3 m (10’) cableHI 7004L pH 4.01 buffer solution, 500 mL bottleHI 7007L pH 7.01 buffer solution, 500 mL bottleHI 7039L 5.00 mS/cm calibration solution, 500 mL bottleHI 70300L Electrode storage solution, 500 mL bottleHI 7061L Electrode cleaning solution, 500 mL bottleHI 710005 115 Vac to 12 Vdc power adapterHI 710006 230 Vac to 12 Vdc power adapterRecommendations for UsersBefore using this product, make sure that it is entirely suitable for theenvironment in which it is used. Operation of this instrument in residentialareas could cause unacceptable interferences to radio and TV equipment.The glass bulb at the end of the electrode is sensitive to electrostaticdischarges. Avoid touching this glass bulb all the time. The metal band atthe end of the EC probe is sensitive to electrostatic discharges. Avoidtouching this metal band all the time. During operation, ESD wrist strapsshould be worn to avoid possible damage to the electrode by electrostaticdischarges. Any variation introduced by the user to the supplied equipmentmay degrade the instrument’s EMC performance. To avoid electrical shock,do not use this instrument when voltages at the measurement surfaceexceed 24 Vac or 60 Vdc. To avoid damages or burns, do not perform anymeasurement in microwave ovens.IST98143 07/05 |
Related manuals for Hanna Instruments HI 98143
Hanna Instruments HI 98140 Instruction Manual
Hanna Instruments HI 981402 Instruction Manual
Hanna Instruments HI 981410 Instruction Manual
Hanna Instruments HI 9810 Instruction Manual
Hanna Instruments HI 9143 Instruction Manual
Hanna Instruments HI 9812 Instruction Manual
Hanna Instruments HI 9812 Instruction Manual
Hanna Instruments HI 981404N Instruction Manual
Hanna Instruments HI 98180 Instruction Manual
Hanna Instruments HI 98190 Instruction Manual
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved