OneStart

Hamilton Sundstrand Company Gas Fuel Metering Valve HFG2.0 User Manual

Page 1 preview
Page 2 preview
Page 3 preview
Page 4 preview
Page 5 preview
Page 6 preview
Page 7 preview
Page 8 preview
Page 9 preview
Page 10 preview
Page 11 preview
Page 12 preview
Page 13 preview
Page 14 preview
Page 15 preview
Page 16 preview
Page 17 preview
Page 18 preview
Page 19 preview
Page 20 preview
Page 21 preview
Page 22 preview
Page 23 preview
Page 24 preview
Page 25 preview
Page 26 preview
Page 27 preview
Page 28 preview
Page 29 preview
Page 30 preview
Page 31 preview
Page 32 preview
Page 33 preview
Page 34 preview
Page 35 preview
Page 36 preview
Page 37 preview
Page 38 preview
Page 39 preview
Page 40 preview
Page 41 preview
Page 42 preview
Page 43 preview
Page 44 preview
Page 45 preview
Page 46 preview
Page 47 preview
Page 48 preview
Page 49 preview
Page 50 preview
Page 51 preview
Page 52 preview
Page 53 preview
Page 54 preview
Page 55 preview
Page 56 preview
Page 57 preview
Page 58 preview
Page 59 preview
Page 60 preview
Page 61 preview
Page 62 preview
Page 63 preview
Page 64 preview
Page 65 preview
Page 66 preview
Page 67 preview
Page 68 preview
Page 69 preview
Page 70 preview
Contents
  1. Table Of Contents
  2. Table Of Contents
  3. purpose of this guide
  4. INSTALLING THE HFG2.0
  5. General Specification Summary
  6. Mechanical Installation
  7. Figure 1-1. Typical HFG2.0 Gas Fuel System Installation
  8. Figure 1-3. HFG2.0 Dimensions, 3-Piece Housing
  9. Figure 1-4. HFG2.0 Dimensions, 1-Piece Housing
  10. Figure 1-5. HFG2.0 Mounting Orientations
  11. Figure 1-6. HFG2.0 Mounting Provisions, 3-Piece Housing (Standard Mounting)
  12. Figure 1-7. HFG2.0 Mounting Provisions, 1-Piece Housing (Standard Mounting)
  13. Figure 1-8. HFG2.0 Mounting Provisions, 1-Piece Housing (Reversed Mounting)
  14. Electrical Connections
  15. Figure 1-9: HFG2.0 System Power Wiring Diagram
  16. Table 1-2. Power Supply Requirements
  17. Table 1-3. Wire Size for HFG2.0 Power Harness
  18. Table 1-4. Wire List for HFG2.0 System Signal Harness
  19. Figure 1-12: HFG2.0 System Signal Wiring Diagram
  20. Figure 1-13. Typical Analog Input Connection
  21. Figure 1-16. Typical Discrete Output Alarm Connections
  22. Table 1-5. Computer COM Port Pin Outs
  23. Table 1-6. Wire Size for HFG2.0 Signal Harness
  24. UNDERSTANDING THE HFG2.0
  25. Electrical Description
  26. Figure 2-1. HFG2.0 Electronics System Block Diagram
  27. Mechanical Description
  28. Figure 2-2. HFG2.0 Cut-Away View – Actuator Main Housing Assembly
  29. Figure 2-3. HFG2.0 Cut-Away View (Partial)
  30. Identification Plate
  31. Figure 2-5. Typical Refurbishment Plate
  32. OPERATING THE HFG2.0
  33. Holding Motor Current State
  34. Figure 3-1. HFG2.0 Basic Operation Flow Chart
  35. Moving to Stop Position
  36. Figure 3-2. HFG2.0 Actuator Position vs. DEMAND
  37. Resetting the Actuator
  38. Monitoring System Health
  39. fault file
  40. Table 3-1. Default Configuration For FAULT Alarm
  41. Table 3-3. Fault Configuration For FAULT Alarm
  42. Table 3-4. Fault Configuration For OVERTEMP Alarm
  43. Changing Set-Up Parameters
  44. Table 3-5. Typical HFG2.0 Setup Parameters With Default Values
  45. MAINTAINING THE HFG2.0
  46. TROUBLESHOOTING
  47. Table 5-1. Initial Installation Troubleshooting Chart
  48. Table 5-3. HFG2.0 Electrical Continuity Troubleshooting Chart
  49. FAULT File
  50. APPENDIX A: DECOMMISSIONING & DISPOSAL
  51. APPENDIX B: GLOSSARY
/ 70
Related manuals for Hamilton Sundstrand Company Gas Fuel Metering Valve HFG2.0
Hamilton Sundstrand Company Fuel Metering Valves eXVG Supplementary Manual first page preview
Hamilton Sundstrand Company Fuel Metering Valves eXVG Supplementary Manual
This manual is suitable for:
Gas Fuel Metering Valve HFG2.0