Halma FORTRESS Alfred Operating Instructions Manual
1Operating Instructions: Alfred Solenoid Controlled Guard LockDescriptionThe Alfred Solenoid Controlled Guard Lock is a robust, heavy duty SolenoidControlled Guard Locking Device which can be used to lock and secure a machineguarding application and/or provide an interlocking function to a machine.A full Alfred Solenoid Controlled Guard Lock product can be configured from aselection of Actuator Modules, Head Modules and can include up to three KeyAdaptors all mounted above an Ex rated Solenoid Module.The Ex rated Solenoid Module at the base of an Alfred Solenoid Controlled GuardLock product contains dual safety circuits and a monitoring circuit which are linkedto the operation and function of the assembled Head Module and / or Key Adaptormodules.The Ex rated Solenoid Module is available in both Power-To-Unlock and Power-To-Lock versions and with and without Safety Circuit monitoring on the Solenoidlocking or unlocking action. See Options and Ordering Information section fordetails.The Alfred Solenoid Controlled Guard Lock’s tough Stainless-Steel enclosuresand IP67 and IP69 sealing protection make it perfect for any heavy duty or regularapplication.As consistent with the rest of the Alfred product range, the Alfred SolenoidControlled Guard Lock is rated for use in Hazardous Locations and ExplosiveAtmospheres (See ATEX, IECEx and HazLoc section below for full product ratings,marking and detail).Approvals and CertificationsImportant:This product is designed for use according to the installation and operating instructions enclosed. It must be installedby competent and qualified personnel who have read and understood the whole of this document prior to commencinginstallation. If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipmentmay be impaired. Any modification to or deviation from these instructions invalidates all warranties. Fortress Interlocks Ltdaccepts no liability whatsoever for any situation arising from misuse or misapplication of this product.This product is not to be used as a Mains Isolator or Emergency Stop. The unit is a component to be added to a permanentelectrical installation meeting the requirements of the applicable IEC/EN standards. This product meets the requirements ofthe standard IEC/ EN 61010-1:2001safety requirements for electrical equipment for measurement control and laboratory use- Part 1 General Requirements.The voltages used within the Alfred Ex Rated Solenoid Module circuits must all be of the same type. i.e. ALL Hazardous Liveor ALL Machine Extra Low Voltage. It is vitally important that the correct version of this unit is selected.DO NOT LEAVE AUXILIARY RELEASE/ MANUAL OVERRIDE KEY IN PLACE! DO NOT REMOVE LID WITH OVERRIDEKEY IN PLACE!Always keep Manual Override Key in a secure place, under management control, as it allows access to areas thatmay have a residual hazard and may result in incorrect operation of some devices.BEWARE OF INTENTIONAL MISUSE CAUSED BY OPERATORS WANTING TO BYPASS SAFETY SYSTEMS. THEINSTALLER SHOULD ASSESS THE RISKS AND MITIGATE AGAINST THEM.IF YOU HAVE ANY QUESTIONS OR QUERIES OF ANY NATURE WHATSOEVER PLEASE CONTACT THE SUPPLIERWHO WILL BE PLEASED TO ADVISE AND ASSIST.APPROVALS PENDING |
Related manuals for Halma EXPXL411
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved