Haier HYCD-282 Operation Manual
Also see for HYCD-282: Service manual
Parametercode Parameter meaning Parametercode Parameter meaningL0 Control temperature setting L3 Current voltage inquiryL1 High temperature alarm value setting L4 Current environment temperature inquiryL2 Low temperature alarm value setting L5 Non-use settingU disk data reading methodU disk interface is on the right of refrigerator-freezer top display board. After inserting U disk tointerface, cabinet will automatically identify and import temperature data. Meanwhile press settingand temperature area switch key on display board for 5s, check whether data is imported to U disk.If not, display screen will show "USB" "……"; or it will show "USB""OK". Unplug U disk afterimporting, and open the data in computer by text or excel. This product can save the cabinettemperature data in recent 10 years, if it is more than 10 years, the previous data will be replacedautomatically.Temperature setting14 151. UnlockWhen the lock indicator lights, all keys are locked except digits switch key, it should be unlockedbefore setting parameters, the unlock steps are as follows:Long press digits switch key for more than 5s, the display area shows F0, 0 digit flashing;Press temperature adjusting key, display area shows F1;Press setting key, lock indicator goes out, and the keyboard is unlocked.2. User parameter settingUser can change the setting temperature, alarm value, start delay and other parameters ofrefrigerating chamber or freezing chamber through control panel. These settings are independent forrefrigerating chamber and freezing chamber. The operations as refrigerating chamber setting will beshown on the display screen of refrigerating chamber on left side of display panel, and the parameteradjustment of freezing chamber will be shown on the refrigerating chamber on right side of displaypanel. The activated setting area will make blinking display, to activate another setting area, youcan press temperature switch key.Parameter inquiry and settingPress setting key under unlock status, the display screen activated by default will show L0, 0 digitflashing, then the temperature area can be changed by temperature area switch;Press temperature adjustment key to adjust L0 to L1, L2, L3, L4, L5;Adjust to designated parameter, and press setting value, the display screen will show the settingvalue of that area, and the value at units' digit will flash, the corresponding list of parameter code isas follows:Press digit switch key to change the flashing digit, press temperature adjustment key to changecurrent digit value;Press setting key when adjusting to required temperature, change and save parameters.The setting temperature by default of cold storage area is 5°C, the frozen area is -40°C;For non-use setting, the default value is 1, meaning the normal operation of current activated area,0 means the current activated area is disabled;Voltage and environment temperature can only be inquired, but can't be set .High-low temperature alarm value can be set within the following range:The highest setting temperature+5°C≥high temperature alarm value≥setting temperature+5°CThe lowest setting temperature-5°C≤low temperature alarm value≤setting temperature-5°CThe “├” in front of figure represents “+”.② Start delay settingIn unlock status, press setting key and temperature adjustment key for 5s, the display screenactivated by default will show the delay time of current area compressor, then the temperaturearea can be changed by temperature area switch;Press temperature adjustment key to change start delay time;Press setting key when adjusting to required value, change and save parameters.③ Freezing chamber defrostIn unlock status, press freezing defrost for more than 5s, the refrigeration system of freezingchamber will stop running, the display screen of cold storage area will show dF, it can't make autoreply in this status, but long press freezing defrost key under unlock status again for more than 5s toexit defrost mode, dF will disappear from display screen of cold storage area after successful exit.In all parameter adjustment, if there is no operation within 10s, system will savecurrent setting and exit parameter setting mode;For parameter adjustment, frozen area setting is activated by default for firstuse, if it needs to switch to cold storage area setting, press temperature switchkey. If it is not for first use, the final set temperature area is activated by default;Application method |
Related manuals for Haier HYCD-282
Haier HYC-260 Operation Manual
Haier HYC-68 Operation Manual
Haier HYC-68 Operation Manual
Haier HYC-68 Operation Manual
Haier HYC-68 Operation Manual
Haier HYC-410 Operation Manual
Haier HYC-940 Operation Manual
Haier HYC-610 Operation Manual
Haier HYC-260-360 Operation Manual
Haier HYC-1378 Operation Manual
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved