HP T2touch PANEL CUSTOMERSUPPORTSERVICE MANUALAux windings: 8.75±7% (25 °C temp.)Motor speed : 2928 rpm (Unloaded)Gas Type: R290Capacitor value : 20 μF ± %5Compressor Capacity: 7.8 cm³/revComponent Test Check whether the compressor cable is connected to the compressor terminal. Check the connection of the capacitor cables Measure the resistance values and check the capacitor values Check whether it is working by connecting via the terminals S,R and C connection If it is working, start the machine and check the drum temperature.The terminals S and R of the motor should be connected with capacitor.Resistance measurement of main winding: Terminal C-R is measured.Resistance measurement of aux winding: Terminal C-S is measured.