HP 3438A Operating And Service Manual
Also see for 3438A: OPERATING & SERVICE MANUAL
Model 3438ASECTION VADJUSTMENT PROCEDURESSection V5-1. INTRODUCTION. 5-7. PRE-ADJUSTMENT PROCEDURES.5-2. This section of the manual contains Pre-Adjustmentand Adjustment Procedures.5-3. EQUIPMENT REQUIRED.5-4. The Test Equipment required for these AdjustmentProcedures is listed in Table 5-1. Equipment that satisfiesthe critical specifications given in the table may besubstituted for a recommended model.5-5. ADJUSTMENT INTERVAL.5-6. Adjustment Procedures should be performed atleast once every year to ensure proper calibration of theMultimeter.piicwA,,,,,IIT i ~ e ~ eAdjcrsrtnenr Proc~rrlctresare,/br use hyqual~/iedpersotznel on!r.. To avoid elec,rric,alsl~uc,k,do nor pei-/:form anl, .rervic,ing orherr/lan rhar contained in [he operaringinsrruc.rions or Perfortnunc,e Tesrs unlc,.ss vouore qualj/i'ecl ro do so.Wear (,lean c,otron g1ove.s n7hen \corking otzthe c,irc,uirhoards or .swirche.s. Cunrat~~inarionq/~/i'nger,~~rinr.son i ~ i g hin~pedat~c.epoit~r.s\t,illdegracle rhe /~c,r/:fort~iunc~e( J / ' rhr insrrunlc,tzr..V.vlon glo1,e.s should nor he ~t.ornd ~ t rl o [hepo.ssihi/irj: (I,/' sraric c,harge hcrildup.The hj,hrid c,ircuirs in rile .Vulrirnerc,r maj. hepertnanenr!r damaged h!. sraric disc,harge,frotn a hand or roo1 u5he11rhe .Vtrlritnertv- isdisassernhled. The, proc,edure.s be lo^. tnusr he,/bllo~z~edro prevc,nr /~o.s.sihle ~latnage.I . Ground rhe hand ~ ) h i l edi.sassetnhlinga t ~ d14,orXingon the .V~tliinlt,rer.Conducri~st,wri.srhand.s (-/I[)- Purr No. 00970-67900) areavailable ,/or rhis p~rrpose.2. Arrac,h rile Mulritnerrr C O M rerrnit~alro earth ground. Touc,/i all tools ro cwrrhground ro ren~ovesraric, c.i~argc,.sht:fore u.singrht7tn on rhe .Ilulritnerer.3. Use a soldering iron with a groutldc,d rip.5-8. Disassembly Instructions:a . Disconnect the Multimeter Power Cord.b. Remove two top cover fastening screws (backpanel) and remove top cover.c. Remove five A3 shield mounting screws (backpanel). This will allow the A3 P C and shield assembly(HP-1B) to slide forward % of a n inch.d . Disconnect W5 from the A3 P C assembly. W5 is agreen, yellow. orange, red, brown cable connecting A3 to4 2 (display).e. Remove the .A3 P C and shield assembly by slidingthe assembly forward and upward. With the Multimeterfront panel facing you, place the A3 PC and shieldassembly to the right side of the Multimeter.f. Re-connect W5 to the A3 P C assemblyg. All adjustments can be made without removing theinternal A l shield.5-9. Test Point and Adjustment Locations.5-10. Fold out and refer t o Figure 5-4. AdjustmentLocator for the remainder of this procedure. 'TheAdjustment Locator shows Test Points. 'Test Jumpers,Adjustment and Connector locations.NOTEThe .Mulritnc,rer .shoctld Lvartn up ,for 15tninures hefbre per/urtning ihe Aclju.srt~~enrProcedure.5-11. ADJUSTMENT PROCEDURE.5-12. Adjustments should be made in the followingsequence:@ A + 7 V Power Supply Adjustment (R417).@ B U725 Back Gate Bias Adjustment (R603).@ 10 kHz Clock Frequency Adjustment (R9).@ A C Zero Adjustment (R203).@ 20 11 Range Zero Adjustment (R11 I). |
Related manuals for HP 3438A
HP 3438B Operating And Service Manual
HP 3438A Operating & Service Manual
HP 3476A Operating And Service Manual
HP 3465B Operating And Service Manual
HP 3490A Operating And Service Manual
HP 3466A Operating And Service Manual
HP 3478A Service Manual
HP 3457A Service Manual
HP 3457A Service Manual
HP 3457A Service Manual
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved