6 = data overrun in host write data (the host wrotemore data than was specified in the request)7 = block mode data transfer is not allowed for therequest8 = data transfer length is too large9 = cannot execute control card request - not enough space254 = transmit not allowed in simplex receive mode255 = receive not allowed in simplex transmit modelength of da ta transferUP 27130AThis field gives the length in bytes of the data transfer initiated by the card for the host read orwrite request.Note that the length does not reflect any early termination initiated by the host. For ex-ample) if the host started a host read request of 200 bytes and the card is able to send 200 bytes,the card will return the length as 200 even if the host invoked END to terminate the transferearly.message type1 = text terminated on single text terminator. The text terminator which terminated the messageis given in byte 64 = text terminated by count5 = text terminated by parity error6 = text terminated by data overrun7 = text terminated by framing error8 = text terminated by alert one condition9 = text terminated by the card, more data coming12 = text terminated by the card, no more data13 = text terminated by buffer overflow14 = host initiated text terminationIIEII = record contains an error4-45