159 TECHNICAL DATA CMX15 CMX18 CM15 CM18Frequency Hz 50 50 50 50Connection 3x400V+N~ Output limited to 18kW; Maximum intensity A - 26.0 - 26.0Output limited to 15kW; Maximum intensity A 21.7 26.0 21.7 26.0Output limited to 13kW; Maximum intensity A 21.7 - 21.7 -Output limited to 12kW; Maximum intensity A 21.7 26.0 21.7 26.0Output limited to 11kW; Maximum intensity A 21.7 - 21.7 -Output limited to 10kW; Maximum intensity A 21.7 - 21.7 -Output limited to 9kW; Maximum intensity A 13.0 13.0 13.0 13.0Output limited to 8kW; Maximum intensity A 13.0 - 13.0 -Output limited to 7kW; Maximum intensity A 13.0 - 13.0 -Output limited to 6kW; Maximum intensity A 8.7 13.0 8.7 13.0Output limited to 5kW; Maximum intensity A 13.0 - 13.0 -Output limited to 4kW; Maximum intensity A 8.7 - 8.7 -Output limited to 3kW; Maximum intensity A 13.0 13.0 13.0 13.0Connection 230V~ single phase 1 1 1 1Nominal maximum intensity 18kW A - 78.3 - 78.3Nominal maximum intensity 15kW A 65.2 65.2 65.2 65.2Maximum converted intensity at 13kW A 56.5 - 56.5 -Maximum converted intensity at 12kW A 52.2 52.2 52.2 52.2Maximum converted intensity at 11kW A 47.8 - 47.8 -Maximum converted intensity at 10kW A 43.5 - 43.5 -Maximum converted intensity at 9kW A 39.1 39.1 39.1 39.1Maximum converted intensity at 8kW A 34.8 - 34.8 -Maximum converted intensity at 7kW A 30.4 - 30.4 -Maximum converted intensity at 6kW A 26.1 26.1 26.1 26.1Maximum converted intensity at 5kW A 21.7 - 21.7 -Maximum converted intensity at 4kW A 17.4 - 17.4 -Maximum converted intensity at 3kW A 13.0 13.0 13.0 13.0S.H.W. available time with 15kW min 5’49” 5’49” - -S.H.W. available time with 13kW min 6’42” - - -S.H.W. available time with 12kW min 7’16” 7’16” - -S.H.W. available time with 11kW min 7’56” - - -S.H.W. available time with 10kW min 8’43” - - -S.H.W. available time with 9kW min 9’41” 9’41” - -S.H.W. available time with 8kW min 10’54” - - -S.H.W. available time with 7kW min 12’27” - - -S.H.W. available time with 6kW min 14’32” 14’32” - -S.H.W. available time with 5kW min 17’26” - - -S.H.W. available time with 4kW min 21’48” - - -S.H.W. available time with 3kW min 29’04” 29’04” - -S.H.W. available time with 2kW min 43’36” - - -Weight kg 70 70 32 32Insulated steel heater header 50 litre stainless steel insulated S.H.W. accumulator No CFC - -Stainless steel plated resistance elements INCOLOY800 S.H.W. - -Stainless steel plated resistance elements INCOLOY800 Heating 6 litre expansion vessel S.H.W. 2 litre expansion vessel - -Electronic regulation of heater modulation Electronic regulation S.H.W.. - -Digital display 0-4 kg/cm2 pressure gauge Accelerator pump Automatic purge TRIACS silent power switches Heating flow detector 100°C heating temperature limiter 80°C S.H.W. temperature limiter - -3kg/cm2 heating safety valve 7kg/cm2 S.H.W. safety valve - -S.H.W. retention valve - -Heating circuit entry valve - -Ambient thermostat intake Anti-electrolysis S.H.W. hoses. - -included 1 using connecting bridge included