Data storage, as shipped from the factory, is as shown in table 2.Table 2Sensor Points FrequencyRadiation 10,000 1 minuteTemperature 1,000 1 minuteBias Voltage 1,000 1 minuteBattery Voltage 1,000 1 minuteWind Speed 1,000 1 minuteWind Direction 1,000 1 minutePressure 1,000 1 minuteRain 1,000 1 hour5.0 SPECIFICATIONS Environmental Radiation Monitor (RSS-131ER)Gamma Measurement— 0-100 R/hr (0-1 Sv/hr)— Accuracy +/-5% at 10microR/hr, +/-7% above 1 R/hr— Angular dependence: <2% over all angles— Sample Rate: 1 second— Operating temperature: -25C to +50CAuxiliary Measurements— Sensor temperature— Battery voltage— High voltage bias—Tipping Rain BucketData Storage— Data recording interval – adjustable 1 second to 9 hours— Data capacity – 20,000 data points— Maximum archive time – 5.5 hours to 20.5 yearsPower— 6 volt internal battery (optional)— Operating current 220mA without modem (250mA with modem)— External battery charger (optional)— Solar power (optional)Real-time clock— Drift <2 minutes/monthSerial Transmission— Three RS-232 ports— Dial-up modem (optional)— Compatible with many externally mounted wireless radio optionsMechanical— 12”X12”X14” overall (31cm x 31cm x 36cm)— 33 lbs (15 kg)— Weatherproof enclosure: Aluminum with two-part catalytic polyurethane paint— Latches and hardware: stainless steelOther Options— Tripod— Rain gauge— Barometric pressure— Wind speed and directionCertifications— CE Certified (Low Voltage Directive and Electromagnetic Compatibility Directive)— CE Pressure Equipment Directive 97/23/EC— ASME Section VIIIENg Edison Park 8499 Darrow Road, Twinsburg, OH 44087 GE EnergyEssential Installation and Operating Instructions forEnvironmental Radiation Monitor (RSS-131ER)Manufactured By Reuter – StokesCAUTIONS AND WARNINGSIF THIS EQUIPMENT IS USED IN A MANNER NOT SPECIFIED BY THE MANUFACTURER, THE PROTECTION PROVIDED BY THEDESIGN OF THIS EQUIPMENT MAY BE IMPAIRED.NO OPERATOR SERVICABLE PARTS. THIS INSTRUMENT SHALL BE SERVICED BY QUALIFIED PERSONNEL ONLY.THE SENSOR ENCLOSURE MAY ONLY BE OPENED BY CUTTING THE LOCK WIRE USED TO SECURE THE LATCHES. LOCK WIREMUST BE REINSTALLED AFTER SERVICING AND SEALING THE ENCLOSURE TO ENSURE CONTINUED SAFETY OF THE PRODUCT.THIS INSTRUMENT DOES NOT INCLUDE PROTECTIVE GROUNDING WIRES. DUE TO THE FACT THAT THIS INSTRUMENT ISBATTERY OPERATED, AND MAY BE MOVED FROM LOCATION TO LOCATION, IT SHALL BE THE RESPONSIBILITY OF THE USER TOPROVIDE APPROPRIATE GROUNDING OF THIS DEVICE WHEN LOCATED IN AN AREA WHERE THIS MAY BE REQUIRED. CONSULTLOCAL ELECTRICAL CODES AND NORMATIVE REGULATIONS FOR APPROPRIATE GROUNDING REQUIREMENTS.THE SENSOR HOUSING CONTAINS A PRESSURIZED IONIZATION CHAMBER WITH HIGH INTERNALPRESSURE AND HIGH VOLTAGE (~400 VDC) ON ITS SURFACE WHEN POWER IS APPLIED. REMOVAL OFCHAMBER FROM ITS PROTECTIVE HOUSING OR MISHANDLING COULD CAUSE SERIOUS INJURY.TO PREVENT DAMAGE TO THE INTERNAL BATTERY AND INTERNAL CIRCUITS, DO NOT CONNECT A SOLAR PANEL AND BATTERYCHARGER SIMULTANEOUSLY.THE (OPTIONAL) INTERNAL BATTERY USED IN THIS INSTRUMENT IS A SEALED LEAD ACID BATTERY AND SHALL ONLY BEREPLACED WITH AN IDENTICAL REPLACEMENT AVAILABLE FROM GE REUTER STOKES. USE OF ANY OTHER BATTERY MAYCAUSE DAMAGE TO THE CHARGING UNIT OR THE INSTRUMENT.RSS-131QSM |
Related manuals for GE SS-131ER
GE PM880 Operations & Installation Manual
GE DewPro MMY 245 Installation And Operation Manual
GE AB-16 Installation Manual
GE PACE 1000 Safety Instructions And User Manual
GE DB-16 Installation Manual
GE AB Series Instructions Manual
GE Aquant Instruction Manual
GE N60 Instruction Manual
GE N60 Instruction Manual
GE D60 Instruction Manual
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved