55Troubleshooting TipsInstallation InstructionsCustomer ServiceOperating InstructionsSafety Information4-Wire Conduit InstallationRemove the 3 screws from the connector block. Remove the grounding strapfrom the connector block middle location and the screw connecting it to theframe of the range. Insert bare wires between the connector block terminalsand movable nuts. Tighten screws securely. Attach ground wire to the frame ofthe range.WARNING: Connector block is approved for copper wire connectiononly. If aluminum wire is used, see note below.NOTE: ALUMINUM WIRINGDo not connect aluminum wire to connector block.Use copper building wire rated for the correct amperage and voltage tomake 3 (three) 3″ copper jumper wires. Connect wire as per Step 6 or 7depending on number of wires.Splice copper wires to aluminum wiring using special connector terminalsdesigned and UL-approved for joining copper to aluminum and follow theconnector manufacturer’s recommended procedure closely.Wire used, location and enclosure of splices, etc., must conform to good wiring practicesand local codes.ba7ScrewFlexible cableBare wire tipsConduitBare wireMovable nutConnector blockBracketConnector block terminalGroundingplate