GE ATS1197 Installation Manual
Also see for ATS1197: Manual
ATS1197Smart card reader with keypadEN DE2006 GE Security B.V. MAINST-ATS1197All rights reserved. Mar 2006www.gesecurity.netnoc dRAS 1RAS 5RAS 9RAS 13RAS 2RAS 6RAS 10RAS 14RAS 3RAS 7RAS 11RAS 15RAS 4RAS 8RAS 12RAS 16EN ATS1197Smart card reader with keypadMounting the unit1. Remove power to the control panel, or 4-door DGP, as applicable.2. Remove the two front panel screws at the bottom of the RAS (seeFigure n), and then remove the RAS back plate. Retain the screwsto secure the RAS later.3. Position the RAS back plate (with the tamper spring at the top)against the mounting surface to determine the locations ofmounting holes and for cabling access (a reduced card readingrange may occur if mounted on a metal surface).4. Mount the back plate on a flat surface using four screws (the holenearest the tamper spring must have a screw in order for thetamper switch to work correctly).5. Terminate the cable, as required (see wiring details below).6. For on-line mode, set the BUS address (DIP switches 1 through 4).For on-line mode, set the TERM switch (DIP switch 5) as required.For off-line mode, the TERM switch must be off (up). See DIP switchsettings for details.7. Mount the RAS on the back plate by engaging the top, and thenlowering the RAS to be flat against the back plate. The rear tamperswitch must be sealed for the system to work correctly. Ensure thatthe back plate tamper spring rests on the tamper switch actuator(protruding from the resin in the back of the RAS) when the RAS is inposition.8. Fix the RAS to the back plate using the two screws removed earlierfrom the bottom of the RAS.9. Apply power to the control panel, or the 4-door DGP.10. For online mode, use an LCD RAS on the BUS (or the systemmanagement software) to program polling and set up the requireditems for the new RAS. In particular, the ATS1197 RAS must beprogrammed as a non-LCD RAS.11. Check that the ATS1197 is communicating correctly and verify thatthe tamper switch is working properly (i.e. "RAS Tamper" is notshowing on the LCD RAS).WARNING:All power should be turned off to the control panel before wiringthe RAS.Location of features (figure n)1. Red/Green dual colour LED.2. Yellow LED.3. Red LED.4. Locking screws.Connecting control panel to keypad RASRefer to the ATS Control Panel Installation Guide for instructions.Tamper switchThe ATS1197 tamper switch is closed when the unit is fitted on themounting plate. In operation, the LCD display will show "RAS Tamper"when not closed.RAS DIP switch settings (figure o)A row of DIP switches is located on the rear of the RAS (figure o) and isused for setting the RAS address and the bus termination (TERM)condition. These settings are described in the following sections.1. RAS address c: Set the RAS address using switches 1 to 4. Switchin "UP" position is off, and switch in "DOWN" position is on.2. TERM switch d: Use switch 5 to set TERM to ‘ON’, if needed. Theremust be no more than two TERM switches or links set to ‘ON’ forany bus. Refer to the control panel installation guide for detailsabout the use of TERM switches or links.# ‘ON’ is indicated as black (down). Example: RAS 2 = On, off, off, off.ConnectionsColour ApplicationRed +12 V nominal (8.5 to 14.0 VDC supply)The RAS can be powered using the bus + and – power fromthe control panel if the distance between the RAS and thecontrol panel does not exceed 100 m (328 feet). Otherwisethe RAS can be powered by AUX PWR from a DGP, or by anauxiliary power supply.Black 0 V (DC supply ground)Green D0/D–/Clock, may be used for D0 (Wiegand data), D–(RS485 data), Magnetic stripe clock. Normal operatingvoltage 0 to +5 V (absolute maximum is +12 V). |
Related manuals for GE ATS1197
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved