4-3Data subject to change without notice 7/07. © 2007 GE DrivesTable 4.2.1 Overview of Contents Displayed for each LevelNo. Level name Content1 Operation Mode2 Program MenuNo. Menu Name Purpose1 DATA SET2 DATA CHECK3 OPR Can check various data on the operating status.4 I/O CHECK5 MAINTENANCE6 LOAD FCTR7 ALM INF8 ALM CAUSE9 DATA COPY Places the function of one inverter in memory for copying to another drive.3 Screen for eachFunctionThe function screen selected on the program menu appears, hence completing the function.4 SupplementaryindividualCan check the latest alarm or simultaneously occurring alarms and alarmhistory. Selecting the alarm and pressing displays alarm contents fortroubleshooting.Functions not completed (e.g., modifying function data, displaying alarm factors) onScreenfunction screens are displayed on the supplementary screen.This screen is for normal operation. Frequency setting from the keypad panel and LED monitor switching arepossible only when this screen is displayed.Each function of the keypad panel is displayed in menu form and can be selected. By selecting the desiredfunction from the list and pressing the corresponding function screen is displayed. The followingfunctions are available as keypad panel functions (menus).The code and name of the function are displayed. Selecting a functiondisplays a data setting screen for checking or modifying data.The code and name of the function are displayed. Select a function to displaya screen for checking data. Modifying data is possible as described above bygoing to the data setting screen.Can check the status of analog and digital input/outputs for the inverter andoptions as an I/O checker.Can check inverter status, life expectancy, communication error status, andROM version information as maintenance information.Can measure maximum and average current and average breaking force inload rate measurement.Can check the operating status and input/output status at the latest alarmoccurrence.FUNCDATAFUNCDATA