Chapter 6 Operation and Troubleshooting> 6.5 TroubleshootingETERNUS DX60/DX80 Disk storage system User Guide180 Copyright 2009 FUJITSU LIMITEDP3AM-3042-03ENZ0Procedure1 Press the controller enclosure’s Power Switch for four seconds or more to turn off theETERNUS DX60/DX80.Drive enclosures with no miniSAS cables connected will remain on.2 Connect the miniSAS cable while the drive enclosure is on.3 Press the controller enclosure’s Power Switch to turn on the ETERNUS DX60/DX80.End of procedure• When the general status of GUI isCheck whether the miniSAS cables (for drive enclosures) are connected in the correct order.If not, reconnect the miniSAS cables in the following order.Procedure1 Press the controller enclosure’s Power Switch for four seconds or more to turn off theETERNUS DX60/DX80, and turn off the AC power.2 Re-connect the miniSAS cable.3 Make sure that power is being supplied, then turn the ETERNUS DX60/DX80 on.End of procedure■ When the FAULT LED blinksCheck the General Status in GUI. A General Status of indicates that the ETERNUSDX60/DX80 contains a component that requires preventive maintenance.Use the Storage System Status screen's device tree to check the detailed information on thecomponent whose image is on, and contact your maintenance engineer.When checking the general status and detailed information on products viaCLI, refer to "ETERNUS DX60/DX80 Command Line Interface (CLI) User'sGuide".Refer "ETERNUS DX60/DX80 Command Line Interface (CLI) User's Guide"