Chapter 3 Setting Up the Server> 3.2 Setting Up Brocade Fibre Channel CardsETERNUS Disk storage systems Server Connection Guide for Oracle Solaris13 Copyright 2010 FUJITSU LIMITEDP3AM-4562-01ENZ0The following procedure shows an example for setting the port speed, topology, and frame datasize.Procedure1 Check the "port_id" of the target port.The port ID checked here is used to set the port speed, topology, and frame data size.2 Set the port speed to "8G".3 Set the topology to "p2p".4 Set the frame data size to "2048".5 Execute the "port disable|enable" command to apply the port speed, topology,and frame data size settings.6 Check the port speed, topology, and frame data size that have been set.• Port speed confirmation• Topology confirmationPort# Type PWWN/MAC FC Addr/ Media State SpdEth dev1/0 fc 10:00:00:05:1e:e7:45:7b 010400 sw Linkup 8G1/1 fc 10:00:00:05:1e:e7:45:7c 010500 sw Linkup 8G# bcu port --listCheck the port ID# bcu port --speed 1/0 8Setting will be enforced after port --disable and -enable# bcu port --topology 1/0 p2pSetting will be enforced after port --disable and --enable# bcu port --dfsize 1/0 2048Setting will be enforced after port --disable and -enable# bcu port --disable 1/0port disabled# bcu port --enable 1/0port enabled# bcu port --speed 1/0Current port speed is: 8GConfigured port speed is: 8G# bcu port --topology 1/0Current topology is: P2PConfigured topology is: P2P