- (01 - 139) -MULTI TYPE2, 3, 4 ROOMS TYPEMULTI TYPE2, 3, 4 ROOMS TYPECOMPLETION OF FUNCTION SETTING MODE(8) Press the "RESET" button.SETTING UP EACH INDOOR UNITRepeat steps (1) through to (8). Steps (1) through to (2)and (8) only need to carried out if the custom code isdifferent to the factory setting of “A”.RESET THE POWER AFTER SETTING UP FUNCTION OF ALL INDOOR UNITSImportantIf the reset is not performed, function can not be read in normally.●After all the functions have been set, the circuit breaker needs to be switched off for at least●2 minutes.After the 2 minutes has passed, power can be restored.The set fuction is stored in the PCB and will remain in memory even when the power is●turned off.However setting function is effective after power reset.Record the function set in the indoor unit on a label, etc., and affix the label to the unit so itcan be used for after-sales service operations.Once the "RESET" button is pressed on the remote controller, the OPERATION MODE will beÜset in the "AUTO MODE".Please adjust the OPERATION MODE to either "COOLING" or "HEATING" before trying tooperate the air conditioner.Note : If CUSTOM CODE is set to anything other than "A" ,the remote control must be setÜaccordingly to the INDOOR UNIT setting.RESETREG1U