OBID i-scan® Installation ID ISC.ANT1700/740-A /-BFEIG ELECTRONIC GmbH Page 53 of 74 M91201-5e-ID-B.doc6.2 Installation ID ISC.ANT.GPC-EContent of the ID ISC.ANT.GPC-E 1. 1 piece Radar connection cable2. 1 piece Radar module3. 2 piece Jumper4. 2 piece spilt rivet 3,0mm5. 1 piece cable-clipStep Action Note1.Attention !!Note: Do not touch the an-tenna surface of the Radarmodule to avoid damagingthe electronic componentsand soiling.2.Set sensitivity of Radarsensor by setting jumper J1and J2.Sensitivity:JP1+2 open: LowJP1 closed: MiddleJP2 closed: HighJP1+2 closed: Very highRecommended Sensitivity:High1.2.4. 3.5.