FEAS PSU90 Operating Instructions Manual
When working with products which are in contact to dangerous electrical voltages, attention mustbe payed to the relevant valid VDE / IEC / EN regulations. Especialy with refrence to the followingrules:VDE 0100, VDE 0550 / 0551, VDE 0711, VDE 0860, IEC 664, IEC 742, IEC 570, IEC 65In case of non-observance of this instructions, the unit or other equipment might be damagedand no warranty or liability could be accepted.When it is necessary to use tools with the units, components parts or subassemblies make itsure, that the power is disconnected from the units and all electric charge which is stored incomponents inside the unit are discharged.Before opening the equipment disconnect the power cord or make sure, that the power is offand the unit is currentless. It is only allowed to set components parts, subassemblies or unitsinto operation, if they are mounted in a shockproof housing. During the installation the unithas to be currentless and the power has to be off.Lifeparts (power cords and leads) which are connected to the units, components orsubassemblies have to be inspected for damage insulation or breaking. If a failure at thepower cord is detected the unit or the subassembly has to be put out of service at once. It is notallowed to reopen the unit or the subassembly before replacing the damaged power cord.It is the user’s responsibility to see that the marginal values of the equipment are not exeeded.If it is not to distinguished for the not industrial ultimate user by the presented operatinginstruction, which electrical data are the correct for the unit or the subassembly, a technicaladviser has always to be asked for technical information.The observance of construction requirements and safety rules (VDE, IEC, employers liabilityinsurenance i.e.) is subject to the user/customer.Beim Umgang mit Produkten, die mit elektrischen Spannungen in Berührung kommen, müssen diegültigen VDE / IEC / EN Vorschriften beachtet werden. Besonders sei auf folgende Vorschriftenhingewiesen:VDE 0100, VDE 0550 / 0551, VDE 0711, VDE 0860, IEC 664, IEC 742, IEC 570, IEC 65Bei Nichtbeachtung der Bedienungsanleitung oder der Anschlußvorschrift, z.B. beiVertauschen der Anschlußklemmen, kann das Gerät oder die Anlage beschädigt werden undder Betreiber verliert seinen möglichen Haftungsanspruch.Werkzeuge dürfen an Geräten, Bauteilen oder Baugruppen nur benutzt werden, wennsichergestellt ist, daß die Geräte von der Versorgungsspannung getrenntsind und elektrische Ladungen die in im Gerät befindlichen Bauteile gespeichertsind, vorher entladen wurden.Vor dem Öffnen des Gerätes den Netzstecker ziehen oder sicherstellen, daß das Gerätstromlos ist. Bauteile, Baugruppen oder Geräte dürfen nur in Betrieb genommen werden,wenn sie vorher in ein berührungssicheres Gehäuse eingebaut wurden. Während desEinbaus müssen sie stromlos sein.Spannungsführende Kabel oder Leitungen mit denen das Gerät, das Bauteil oder dieBaugruppe verbunden sind müssen stets auf Isolationsfehler oder Bruchstellen untersuchtwerden. Bei Feststellen eines Fehlers in der Zuleitung muß das Gerät unverzüglich aus demVerkehr genommen werden, bis die defekte Leitung ausgewechselt worden ist.Der Anwender hat dafür Sorge zu tragen, daß die angegebenen Gerätedaten nichtüberschritten werden.Wenn aus den vorgelegten Beschreibungen für den Anwender oder Erwerber nicht eindeutighervorgeht, welche Kennwerte für ein Gerät oder Bauteil gelten, so muß stets ein Fachmannum Auskunft ersucht werden.Im übrigen unterliegt die Einhaltung von Bau- und Sicherheitsvorschriften aller Art ( VDE, TÜV,Berufsgenossenschaften ) dem Anwender / Käufer.Allgemeine Sicherheitsvorschriften : General safety rules :- konformBetriebsanleitungBitte sorgfältig beachten!Operating instructionsPlease observe carefully!PSU90 / 100PSU140 / 160Anschlußschema 115V/230V / Cable arrangement 115V/230VLaststromdiagramm / Load-current diagram00 102 4 6 851015202530 yp 4VT 2 24V12VTy 12p VVolt DCAmp.Ausgangsstrom / Output currentAusgangsspannung / Output voltageEingangsspannungstoleranzFrequenzVerbrauch PSU90 / 100 / 140 / 160Eingangsstrom PSU90 / 100 / 140 / 160AusgangsgrößenAusgangsspannungen UNENNAusgangsstrom INENNRestwelligkeitBetriebsdatenEinschaltdauer (ED)ArbeitstemperaturTemperaturkoeffizientLagertemperaturbereichWirkungsgradKühlungSchutzeinrichtungenVorsicherung PSU90 / 100 / 140 / 160AusgangssicherungÜberlastschutzNetzausfallüberbrückungMTBFSicherheitsdatenPrüfspannung TrafoHochspannungsfestigkeitLuft- und KriechstreckenFunkenentstörgradAnwendungsklasseUmgebungsfeuchteSchutzart GehäuseSchutzart KlemmenRüttelfestigkeitAngewandte Bauvorschriftengemäß VDEIECENCSA / ULMechanikBefestigungMaße PSU90PSU100PSU140PSU160MaßeMaßeMaßeGewicht PSU90 / 100 / 140 / 160Eingangsspannung siehe Gehäuseaufdruck des Gerätes+15% und -15%45 - 66 Hzmax. 65VA / 105 VA / 140VA / 175VAmax. 0,3A / 0,5A / 0,65A / 0,8Asiehe Gehäuseaufdruck des Gerätessiehe Gehäuseaufdruck des Gerätes< 3%100%-40°C bis +70°C< 500ppm / K-40°C...+105°Cca. 87%natürliche Konvektion (S)5,0Amp. trägenicht erforderlich da kurzschlußfest20 mSek. typ.> 400.000 h5 kVac gemäß VDE 0551Eingang / Ausgang 3,75 kVacnach VDE 0806 / IEC 380Primärkreis - Sekundärkreis >8mmnach VDE 0110< K nach VDE 0871 und EN 55022/BKSE nach DIN 4004095% relative Feuchte im JahresdurchschnittBetauung möglich - tropentauglichIP 65IP 20 (VGB4)>30g bei 33Hz in X, Y und Z,nach IEC 68 und DIN 41640VDE 0100, 0110, 0113, 0551, 0160, 804-8IEC 380, 742, 950EN 60950, EN50081, EN50082CSA 22.2 / UL1012Auf Schiene nach DIN 4627747mm x 99mm x 118mm BxHxT)64mm x 99mm x 118mm (BxHxT)79mm x 99mm x 118mm (BxHxT)94mm x 99mm x 118mm (BxHxT)ca. 1,3kg / 1,85kg / 2,35kg / 2,85kgInput voltageConsumption PSU100 / 140 / 160Input current PSU90 / 100 / 140 / 160Output dataOutput voltage UNOMINALOutput current INOMINALResidual rippleOperating dataDuty circleOperating temperatureTemperature coefficientEfficiencyCoolingSafety devicesOutput fuseOverload protectionHold-up timeMTBFSafety dataTest voltage transformerHigh-voltage resistanceAir gaps and leakage pathsDegree of EMI suppressionClass of applicationAmbient humidityProtective class enclosureProtective class terminalsVibration proofApplied construction regulationsaccording to VDEIECENCSA / ULMechanicsMountingDimensions PSU90PSU100PSU140PSU160DimensionsDimensionsDimensionsWeight PSU90 / 100 / 140 / 160Eingangsgrößen Input dataInput voltage toleranceFrequencyStorage temperature rangeFuse for input PSU90 / 100 / 140 / 160Technische Daten Technical Dataim Gerät integriertDie Geräte sind für sinusförmige Eingangsspannungen ausgelegt.Ausgang Potentialfrei nach VDE 0551Technische Daten siehe Tabelle rechts.see face plate+15% and -15%45 - 66Hzmax. 65VA / 105 VA / 140VA / 175VAmax. 0,3A / 0,5A / 0,65A / 0,8AEN 60950, EN50081, EN50082see face platesee face plate< 3%100%-40°C to +70°C< 500 ppm / K-40°C...+105°Cca. 87%selfcooling (S)5,0 Amp. delayednot necessary - cont. short-circuit proof20 msec. typical> 400.000 h5 kVac in accordance to VDE 0551Primary circuit - secondary circuit 3,75 kVacacc. to VDE 0806 / IEC 380Primary circuit - secondary circuit >8mmacc. to VDE 0110< K in acc. to VDE 0871 and EN 55022/BKSE according to DIN 4004095% rel. humidity, yearly average dewingallowed for use in tropical ambientIP 65IP 20 (VGB4)>30g at 33Hz in X, Y and Z,acc. to IEC 68 and DIN 41640VDE 0100, 0110, 0113, 0551, 0160, 804-8IEC 380, 742, 950CSA 22.2 / UL1012on rails acc. to DIN 4627747mm x 99mm x 118mm (W x H x D)64mm x 99mm x 118mm (W x H x D)79mm x 99mm x 118mm (W x H x D)94mm x 99mm x 118mm (W x H x D)ca. 1,3kg / 1,85kg / 2,35kg / 2,85kgintegrated into deviceDie Geräte vom Typ PSU100 / 140 / 160 sind anschlußfertige,ungeregelte Netzgeräte.Tropentauglich - GießharzvollvergußDie grüne LED signalisiert den Betrieb des Gerätes.Kurzschlußfest, leerlauf- und überlastsicherDie Geräte eignen sich zur Montage auf 35mm Hutprofil-schienen . Befestigungsalternativen sieheR ckseite dieser Bedienungsanleitung.gemäß DIN 46277üThe power supplies are suitable to be fitted on 35mm rail. Mounting alternatives are shown on backpage.acc. to DIN 46277The correct operation of the unit is indicated by the green LED.Short- circuit proof, no-load and overload safeSuitable for the tropics - Epoxy resin castedOutput separated according to VDE 0551The units are constructed for sinus-oidal input voltage.The power supply units of the series PSU100 / 140 / 160 areready for installation on delivery.Technical data see table on the right side.Vorsicherung PS1U90 / 100 / 140 / 160Vorsicherung PS2U100 / 140 / 1608,0 Amp. träge2,0 Amp. trägeFuse for input PS1U90 / 100 / 140 / 160Fuse for input PS2U100 / 140 / 1608,0 Amp. delayed2,0 Amp. delayedGmbHPostfach 1521D - 22905 AHRENSBURGTelefon: 04102 - 42082Telefax: 04102 - 40930www.feas.de© 2004 ®Eingangsstrom PS1U90 / 100 / 140 / 160Eingangsstrom PS2U100 / 140 / 160max. 0,6A / 1,0A / 1,25A / 1,6Amax. 0,3A / 0,4A / 0,5AInput current PS1U90 / 100 / 140 / 160Input current PS2U100 / 140 / 160max. 0,6A / 1,0A / 1,25A / 1,6Amax. 0,3A / 0,4A / 0,5APS2U100Netzspannungline-voltagePS2U100 - 400 V~+-VerbraucherconsumerL1PEL2PSU100 / PS1U100+-VerbraucherconsumerNetzspannungline-voltagePSU100 - 230 V~PS1U100 - 115 V~L1PENPSU140 / PS1U140+-VerbraucherconsumerNetzspannungline-voltagePSU140 - 230 V~PS1U140 - 115 V~L1PENPS2U140+-VerbraucherconsumerNetzspannungline-voltagePS2U140 - 400 V~L1PEL2PSU160 / PS1U160PS2U160Netzspannungline-voltagePS2U160 - 400 V~+-VerbraucherconsumerL1PEL2006 1251015202530Typ 24V 24V12VyT p 12VPSU160Volt DCAmp.Ausgangsstrom / Output currentAusgangsspannung / Output voltage bei nominaler Eingangsspannungat nominal input voltage3 9PSU100bei nominaler Eingangsspannungat nominal input voltage15Anschlußschema 400V / Cable arrangement 400V+-VerbraucherconsumerL1PENPSU90 / PS1U90Netzspannungline-voltagePSU90 - 230 V~PS1U90 - 115 V~ |
Related manuals for FEAS PS1U100
FEAS PSU30 Operating Instructions Manual
FEAS PSU180 Operating Instructions Manual
FEAS PSU 180 Operating Instructions Manual
FEAS PSU500T-K Operating Instructions Manual
FEAS PSW7012 Operating Instructions Manual
FEAS LDR90 Operating Instructions Manual
FEAS PSU75040-K Operating Instructions Manual
FEAS LDR50 Operating Instructions Manual
FEAS LDR40 Operating Instructions Manual
FEAS PS5U750130 Operating Instructions Manual
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved