Product DescriptionRev. A191.3.3 Optional InterfaceThe EPSON Stylus COLOR 1520 supports an optional Type-B interface (Level 2) with the followingcharacteristics.âReply messageÑWhen ESC/P2 is selected:Main type :MTP48p, PW136cl10cpi, PRG(W0xxxx)rev, AP800ma, SPD0fastProduct name :Stylus COLOR 1520Emulation type :ESCPL2-00Entity type :EPSONLQ2ÑWhen X24E is selected:Main type :MTP48p, PW136cl10cpi, PRG(W0xxxx)rev, AP800ma, SPD0fastProduct name :Stylus COLOR 1520Emulation type :PRPXL24-00Entity type :EPSONPRPXL24Option command No. command name Reply-A Reply-B00h No Operation Accept None01h Start Hard Ware Reset Accept Excute OK02h Start Soft Ware Reset Reject03h Send Main System Type Accept04h Send Name Data Reject05h Inquire Name Data Accept06h Send Product Name Accept07h Send Soft Ware Emulation Type Accept08h Complete Buffered Data Accept Check Condition09h Stop Procedure Reject Execute OK0Ah Return Buffered Data Reject0Bh Send Entity Type Accept0Ch Send Status Accept0Dh Quit Procedure Reject0Eh Inquire ASCII Message Reject0Fh Send ASCII Message Accept None10h - 13h Unknown None14h Inquire Emergency Message Accept Execute OK15h Send Emergency message Accept16h - 1Fh Unknown None20h - FFh Reserved NoneMain Command No. Command name Sending Timing01h Start Software Reset Ñ/INIT signal on the std. parallel I/FÑType-B I/F option command : 01hÑCold Start04h Send Name Data ÑType-B I/F command : 05h07h Inquire Software Emulation Name ÑChanging software Emulation Type0Eh Inquire ASCII Message ÑWriting to DBIN register14h Inquire Emergency Reply ÑReply for Emergency command15h Send Emergency Message ÑReceive Emergency CommandâEmergency Command0X00 :Get device ID0X01 :Get all statusâSending BDC-ST through DBIN registerWhen State-Reply is set “ON”, by ST from Type-B I/F, sending BDC-ST through DBIN register isstarted. When State-Reply is started, “Start” and “End” of BDC-ST characters are announced bysending the Main command 0Eh.Table 0-21.Reply for Option CommandTable 0-22. Supported Main Command and Sending Timing