Epson Artisan 700/Epson Stylus Photo PX700W/TX700W Revision CDISASSEMBLY/ASSEMBLY Disassembly/reassembly procedures specific to Artisan 700/PX700W/TX700W 188Confidential4.3.1.3 Upper Housing (Artisan 700/PX700W/TX700W) Parts/Components need to be removed in advance:Scanner Unit/Upper Left Housing/Paper Guide Top Assy Removal procedure1. Remove the screw (x1) and release the Grounding Wire.Figure 4-210. Releasing the Grounding Wire2. Release the hooks (x5) of the Panel Unit Front Cover. (See Fig. 4-211)3. While pushing the Panel Lock Button, slide the Panel Upper Cover in thedirection of the arrow to release the hook (x8) of the Panel Upper Cover, andremove the Panel Upper Cover.Figure 4-211. Removing the Upper Housing (1)CHECKPOINTThe disassembly/reassembly procedures for Artisan 800/PX800FW/TX800FW differ from those of Artisan 700/PX700W/TX700W, see4.2.2.5 "Upper Housing" (p107) for the procedures.CAUTIONThe Grounding Wire is attached to the frame with a screw. Becareful not to deform the frame when removing the screw.C.B.S. 3x6 (8±1Kgfcm)GroundingWirePanel Unit Front CoverPanel Lock ButtonPanel UnitPanel Upper CoverHook of the Panel Upper CoverHook of the Panel Unit Front Cover