33EnglishDIP switch 2(*1)The “Y-connection enable” is set when a TM printer with no modular jack for theDM-D is connected with this product, using one COM port to connect both TMprinter and DM display. In this case, an optional DM-D stand (DP-501) and aconnecting cable are required. In the cases other than above, choose“Y-connection disable” (default setting).(*2)This function can select whether or not you perform self test when turning on thepower. See “Self Test” for details.(*3)When selecting “20 column and 2 line mode,” this product can be used like theDM-D105/106/205/206. In this case, the graphic display and the original functionsfor the DM-D500 cannot be used, but when selecting “256 × 64 dots mode,” theycan be used.(*4)When setting to “Printer is selected,” data is sent to the TM printer, but is notdisplayed on the display. When setting to “Display is selected,” data is displayedon the display but is not output from the TM printer.The selection can be changed using command.(*5)Stay at OFF setting.Note:❏ The changes in the DIP switch setting are effective when the power isturned on again.❏ The data transmission setting, such as data length, transmission speed,must be the same on both your computer and printer.DSW2 No. Function ON OFF Default setting2-1 Y-connection (*1) Enable Disable OFF2-2 Self test selection (*2) Perform self test Do not perform OFF2-3 20 column and 2 linemode selection (*3)20 column and2 line mode256 ¥ 64 dotsmodeOFF2-4 Device selectiondefault settingPrinter isselectedDisplay isselectedOFF2-5 Address 0 The display device number(1-7) corresponds to Address num-ber 0 to 2.(All OFF are regarded as no dis-play number.)OFF2-6 Address 1 OFF2-7 Address 2 OFF2-8 Reserved (*5) - Fixed to OFF OFF