AA) The by-pass screw• If you change from natural gas G20 20mbar to liquid gas, fully tighten the by-pass screw in.• If you change from liquid gas to naturalgas G20 20 mbar, undo the by-passscrew approximately 1/4 of a turn (1/2of a turn for Triple Crown burner).WARNING!Make sure the flame does not goout when you quickly turn theknob from the maximum positionto the minimum position.8.4 Electrical connection• Ground the appliance according tosafety precautions.• Make sure that the rated voltage andtype of power on the rating plate agreewith the voltage and the power of thelocal power supply.• This appliance is supplied with a mainscable. It has to be supply with a correctplug, able to support the load markedon the rating plate. The plug has to befitted in a correct socket.• Any electrical component must be in-stalled or replaced by the Service ForceCentre technician or qualified servicepersonnel.• Always use a correctly installed shock-proof socket.• Make sure that there is an access tothe mains plug after installation.• Do not pull the mains cable to discon-nect the appliance. Always pull themains plug.• The appliance must not be connectedwith an extension cable, an adapter ora multiple connection (risk of fire).Check that the ground connection is inconformity with the standard and regu-lations force.• The power cable must be placed insuch a way that it does not touch anyhot part.• Connect the appliance to the mainswith a device that lets to disconnect theappliance from the mains at all poleswith a contact opening width of mini-mum 3 mm, eg. automatic line protect-ing cut-out, earth leakage trips or fuse.No part of the power cable must heat to atemperature of more than 90° C.Use clamps installed on the side of thecabinet to prevent contact with the equip-ment below the cooktop. See an exampleof an optimal path in Figure.AA) Rigid copper pipe or flexible pipe instainless steel8.5 Replacement of theconnection cableTo replace the connection cable use onlyH05V2V2-F T90 or equivalent type. Makesure that the cable section is applicable tothe voltage and the working temperature.The yellow/green earth wire must be ap-proximately 2 cm longer than the brown(or black) phase wire.8.6 Building Inmin. 600 mmmin. 55 mmmin. 650 mm560 mm480 mmmin. 200 mm30 mm12 www.electrolux.com