Datexel PRODAT-04 Quick Start Manual
Via monte Nero, 40/B – 21049 TRADATE (VA) ITALYPhone: +39 (0)331841070 Fax:+39 (0)331841950 - e-mail:datexel@datexel.it - www.datexel.itConfiguration interface forserial ports RS-232GENERAL DESCRIPTIONThe configuration interface PRODAT-04 allows to program, by dedicated software, all the DATEXEL devices of the SMART and SLIM series using both fixedworkstations and laptops with communication serial ports RS-232 on board.An internal battery is available for the eventual supply of the transmitter on programming; the battery's output voltage is provided on the connector J4; the samevoltage is used to power the interface when the output voltage of the serial port is lower of the minimum voltage value necessary to the right working of thedevice (± 7Vdc).The 1500 Vac galvanic isolation between the lines of input/power supply and output is obtained by means of opto-couplers on the data lines and a DC/DCconverter on the power supply.By the dedicated cable (CVPR-03) it is possible to configure the Intrinsically Safe devices.With the PRODAT-04 are provided the standard cable CVP or the cable CVPR-03, the CD-ROM containing the drivers to install the programming software andtwo Jack connectors for the terminals J3 and J4.The configuration interface PRODAT-04 is in compliance with the Directive 2004/108/EC on the Electromagnetic Compatibility.FEATURES- Adapt to configure the devices of SMART and SLIM series- Galvanic isolation between the transmission and receiving sides- Internal battery- Connector for external supply input- Connector for external supply output- EMC compliant – CE mark- Programming of the DATEXEL devices, on field tooUSER INSTRUCTIONSA) Use with Standard devices.The device on programming must be always powered as shown on its technical data-sheet.The interface PRODAT-04 must be connected to the serial port RS-232 by pin-to-pin cable to the connector J1 ; connect the ' CVP ' cable from the connector J2to the PRGM connector of the device on programming.It is also possible to power the device on programming using the internal battery (only for transmitters) connecting the connector J4 to power supply terminal ofthe transmitter.B) Use with Intrinsically Safe devices.The device on programming must be always connected in according to the Safety Specifications reported on the technical data-sheet of the device .The configurable devices are the following:- DAT 1010 IS , DAT 1010 IS/HT;- DAT 1015 IS , DAT 1015 IS/HT;- DAT 1065 IS , DAT 1065 IS/HT;- DAT 2015 IS , DAT 2015 IS/HT;- DAT 4035 IS , DAT 4035 IS/HT.The connection diagrams A and B are shown on next page in the section “PRODAT-04: Connections”.To use the PRODAT-04 refer to the section “Installation Instructions”.PRODAT-04Type of battery ( Optional ) 6LF22 / 9 VdcExternal supply ( Optional ) 10 ÷ 30 Vdc (Transmitters)18 ÷ 30 Vdc (Converters)Current consumption < / =10 mARS-232 connection (pin-to-pin cable) DB9 connectorCVP/CVPR-03 connection 4 ways RJ11 plugExternal supply IN connection 2.1 mm JACK connectorExternal supply OUT connection 2.5 mm JACK connectorGalvanic isolation among the ways 1500 Vac, 50 Hz, 1 minuteElectromagnetic Compatibility Emission: EN 61000-6-3Immunity: EN 61000-6-1Operative temperature 0 ÷ 40 °CStorage temperature (without battery) -20 ÷ 60 °CRelative Humidity (not condensing) 0 ÷ 90 %Weight about 250 g.Optional accessories - CVPR03 for the programming of SMARTseries DAT xxxx IS modules suitable forapplication in hazardous areasTECHNICAL SPECIFICATIONS (Typical at 25 °C and in nominal conditions) |
Related manuals for Datexel PRODAT-04
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved