TMSetupSystem SetupBefore setting up the EVO upgrade system, make sure that you know how the sections areconfigured on the machine.Common system configurations with 20-in spacing include:Section NumberBoom Width in ft Number ofSectionsNozzlesPer SectionTotalNozzles 1 2 3 4 5 6 780 6 6-9-9-9-9-6 48 6 9 9 9 9 690 5 9-15-6-15-9 54 9 15 6 15 990 6 9-9-9-9-9-9 54 9 9 9 9 9 9100 6 12-9-9-9-9-12 60 12 9 9 9 9 12120 7 9-9-14-8-14-9-9 72 9 9 14 8 14 9 9Fig. 2:1. Press the POWER button (1) on the cab box display to turn on the display.2. Press the MENU button (2) to go to the Main Menu screen (3).3. Use the arrow buttons (4) to go to the Advanced Menu line (5).4. Press the ENTER button (6).5. Use the arrow buttons to go to the Section Size line (7) on the Advanced Menu screen.6. Press the ENTER button.7. On the Section Size screen, Section #1 Nozzles is selected (8), press the ENTER button.8. Enter the correct number of nozzles for that section.9. Press the ENTER button.10.Use the arrow buttons to go to the line for the next section (9).11.Press the ENTER button.© 2019 Capstan Ag Systems, Inc. 12 EVO Upgrade