4-134<007: ATT transmission level>Use it to set the transmission level (ATT).Raise the transmission level if errors occur frequently at time of communication because ofthe condition of the line. (It means close to 8)MEMO:Any of the following error codes may be indicated at time of transmission because ofthe line condition:##100, ##101, ##102, ##104, ##201, ##280, ##281, ##282, ##283, ##284, ##750,##752, ##754, ##755, ##757, ##759, ##760, ##762, ##764, ##765,##767, ##769, ##770, ##772, ##774, ##775, ##777, ##779, ##780, ##782, ##784,##785, ##787, ##789Any of the following error codes may be indicated at time of reception because of theline condition:##103, ##106, ##107, ##201, ##793##103, ##106, ##107, ##201, ##793<008: V.34 modulation speed upper limit>Use it to set an upper limit to the modulation speed (baud rate) for the V.34 primarychannel.<009: V.34 data speed upper limit>Use it to set an upper limit to the data transmission speed for the V.34 primary channelbetween 2.4K and 33.6K bps in increments of 2400 bps. (0: 2.4K to 13:33.6K bps).<010: Frequency of the pseudo CI signal>You may select a frequency for the pseudo CI signal.Some types of external telephones do not ring when the fax/tel switch-over function is ON.To sound the ring, change the pseudo CI signal.#NUMERICNumerical Parameter CompositionNo. Item Range of settings002 RTN transmission condition(1) 1% to 99%003 RTN transmission condition (2) 2 to 99 item004 RTN transmission condition (3) 1 to 99 lines005 NCC pause time length (pre-ID code) 1 to 60 sec006 NCC pause time length (post-ID code) 1 to 60 sec010 line condition identification time length 0 to 9999 (10 msec)011 T.30T1 timer (for reception) 0 to 9999 (10 msec)013 T.30 EOL timer 500 to 3000 (10 msec)015 hooking detection time length 0 to 999016 time length to first response at time of fax/tel switchover 0 to 9017 pseudo RBT signal pattern ON time length 0 to 999018 pseudo RBT signal pattern OFF time length (short) 0 to 999019 pseudo RBT signal pattern OFF time length (long) 0 to 999020 pseudo CI signal pattern ON time length 0 to 999021 pseudo CI signal pattern OFF time length (short) 0 to 999022 pseudo CI signal pattern OFF time length (long) 0 to 999023 CNG detection level at time of fax/tel switchover 0 to 7024 pseudo RBT transmission level at time of fax/tel switchover 10 to 200 to 20 (120/230V)025 Answering machine connection function signal detection time 0 to 999027 preamble detection time length for V21 low-speed flag 20 (x 10ms)051 Hooking detection threshold053 Setting of DTMF call origination count at remote reception of fax054 Setting of busy tone output time when handset is used055 acquisition period of environmental log data 0 to 480 (60min)056 display the type of soft counter 1 101 (Fixed)057 Display the type of soft counter 2 0 to 999058 Display the type of soft counter 3 0 to 999059 Display the type of soft counter 4 0 to 999060 Display the type of soft counter 5 0 to 999061 Display the type of soft counter 6 0 to 999074 e-RDS RGW port number075 Interval of transmission for e-RDS 3rd partyT-4-28T-4-28