Chapter 22-612.7 Power Supply2.7.1 Power Supply Route (Finisher Unit) 0009-2555When the power of the host machine is turned on, 24 VDC is supplied from the host machine to the finisher controllerPCB through two power supply lines. 24 VDC supplied through one power supply line is used to drive motors andsolenoids. 24 VDC supplied through the other power supply line is converted into 5VDC by the regulator IC (IC102)on the finisher controller PCB and then used to drive the sensors on the PCB. Furthermore, it is converted into 3.3VDC by the regulator IC (IC109) on the finisher controller PCB and then used to drive the ICs on the PCB. Both arealso supplied from the finisher controller PCB to the saddle stitcher controller PCB.If the Puncher unit, which is an optional, is installed, they are supplied to the punch controller PCB as well.24VDC for specific motor drives is cut off when the front cover switch (MSW101) is open. This is not applied tothe optional puncher unit and some other motors.A block diagram of power supply is shown below.F-2-822.7.2 Protection Function (Finisher Unit) 0009-2556The 24 VDC for motor and solenoid drive has a fuse or motor driver with over-current protection function for over-current protection.2.7.3 Power Supply Route (Saddle Stitcher Unit) 0009-2557When the power switch of the host machine is turned on with the door closed, 24 VDC is supplied from the finishercontroller PCB to the saddle stitcher via two power supply lines.Saddle stitchercontroller PCBFront cover switch(MSW101)3.3V5V24V24V24V24V5V24VSensorsLogicPunch controller PCB(Puncher Unit(option))MotorSolenoidMotorMotor (M103,M104,M109)Feeder driverPCB(IC109)HostmachineFinisher controllerPCB24VR24VRegulatorIC(IC102)RegulatorIC