CHAPTER 10 TROUBLESHOOTINGCOPYRIGHT © 1999 CANON INC. CANON NP6320 REV.0 DEC. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)10-70IX. SELF DIAGNOSISA. Self-DiagnosisThe DC controller PCB has a microprocessor that diagnoses the functions of the copier (par-ticularly the sensors) at appropriate intervals. If this microprocessor detects an error, it will displaythe type of the error on the indicator on the control panel.The table below shows the various fault codes, their meaning, and the corresponding detectiontiming.Example of E000 code indication:EÛ000 light alternately.Main causeThermistor (TH1), Fixing heater (H1),Power supply PCB, DC controllerPCB or Thermoswitch (TS1).Thermistors (TH1/TH2), Fixingheater (H1), Power supply PCB orDC controller PCB.Main motor error:Main motor (M1), DC controllerPCBCounter, DC controller PCBE000E001Code displayed Fault criteria•If the fixing assembly temperature islower than 50°C after 15 sec fromthe power on. (main thermistor)•If the warm-up is not over after 60sec from when the temperaturereached 50°C. (main thermistor)•If the fixing unit temperature dropsbelow 50°C while the copier is instand by or copying (main ther-mistor)•If the temperature remains 220°C orhigher for 0.1 sec or longer (mainthermistor)•If the temperature difference be-tween the main thermistor and theauxiliary thermisor is 50°C orhigher.•If the HTON signal is on whileHTRD signal is off.If the main motor speed feedbacksignal does not appear after 2 secfrom the main motor.If the break signal is emitted con-tinuously for 0.1 sec or more whenthe counter is not being driven.E030E010Download Service Manual And Resetter Printer at http://printer1.blogspot.com