22 2-92-9Technical Overview > Document Exposure/Feeder System > Document Feeder System > Various ControlTechnical Overview > Document Exposure/Feeder System > Document Feeder System > Various Control■ Various Control● Original DetectionThere are two types of original detection in this equipment.1. Original Presence / Absence DetectionDetected by DS (Document SensorSetting the original onto the original tray pushes up the actuator, activating (light shielded=>light transmitted) the DS, and resulting in detection of the presence of original.2. Detection of the End of the OriginalDetected by the DES (Document End Sensor)The leading edge of the original that is fed pushes up the actuator, activating the DES (lightshielded =>light transmitted) and resulting in detection of the reach of the leading edge oforiginal. Furthermore, when the trailing edge of the original passes the actuator position,the actuator returns to the original position, inactivating the DES (light transmitted => lightshielded). The trailing edge of the original is detected by this mechanism. The originallength that can be scanned with this equipment is less than 400 mm. Passing of the originallonger than this results in jam stop. The original length is calculated by the time it takesfrom detection of the leading edge of the original to detection of the trailing edge of theoriginal.Note:There is no function to detect the original size (original width, length) in this equipment.In the case of SADFSCNTJ151 2 3 4 5 6VCCGNDDESVCCGNDDSDocumentEnd SensorDocumentSensorIn the case of DADFSCNTJ15VCCGNDDESVCCGNDDSDocumentEnd SensorDocumentSensor1 2 3 4 5 6F-2-12F-2-13