COPYRIGHT © 1999 CANON INC. CANON CLC1120/1130/1150 REV.0 MAR. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON) 9-25CHAPTER 9 EXTERNALS / AUXILIARY MECHANISMSD. Flywheel1. Removing the FlywheelCaution:The copier’s flywheel weighs a total of13 kg, consisting of a 8-kg flywheel anda 5-kg flywheel. Take full care not todrop it, and be sure to hold it on its rightand left as shown when handling it.1) Remove the rear cover.2) Turn the flywheel counterclockwise sothat it is as shown in the figure.Caution:Do NOT turn the flywheel clockwise.Otherwise, it will damage the cleaningblade, causing cleaning faults.Figure 9-7213) Remove the two screws [1], and detachthe flywheel 1 [2].4) Remove the two screws [3], and detachthe flywheel 2 [4].Figure 9-720figure 9-7222. Points to Note When Handling theFlywheelThe flywheel 1/2 has its face and its back.Be sure to mount it so that the weight cautionlabel is in view (toward the rear cover).[1][2][4][3]