Camille Bauer KINAX 2W2 Operating Instructions Manual
Also see for KINAX 2W2: Operating instructions
Contents |
3M34.5 low4830 ±0.1120° 7 26.1Ø1/4˝(6.35 g6) Ø 20 f7Ø 40 f711 121.5–0.005–0.0146Ø2Fig. 6. KINAX 2W2 with special drive shaft at front and at rear.Front: dia. 1/4ʺ, length 12 mm [0.472ʺ]. Rear: dia. 2 mm, length 6 mm [0.078ʺ,0.236ʺ].6. MountingMechanical mountingAll versions of the transmitter can be mounted either directly or by means of 3mounting clips to the item being measured. Both methods of mounting and therelevant drilling and cut-out plans can be seen from Table:Mounting versions2 Drilling and cut-out diagramsfor mounting transmitters)directlyM34.5 low[0177]90012 24360600Load max. [Ω] withoutput 20 mAPower supply [V]3010with 3 clamps65 ±0.1M4120°40 + 0.025+ 0[1.574][2.559]Mounting/positioningThree M3 screws are needed for the “directly” mounted versions and three M4screws for those “with clamps”. The screws are not supplied, because the requiredlength varies according to the thickness of the mounting surface.When deciding where to install the transmitter (measuringlocation), take care that the “Ambient conditions” given inSection “5. Technical data” are not exceeded.Angular position transmitters of the KINAX 2W2 range do not require a mechani-cal zero position mark (however, this is made if required by the customer). Aftermounting, the transmitter can be moved to any position and configured using the2W2 software. A power supply connection to the KINAX 2W2 is not required inorder to use the 2W2 configuration software (Fig. 7; AUX switch on the PK 610 inthe ON position.The angular position transmitter must only be programmedoutside of the Ex areal!Programmingconnector InterfaceKINAX 2W2PK 610Ancillary cableOFFONOFF: Power supplyby measuring output(Fig. 10)ON: Power supplyprovided by PCFig. 7. Connection diagram programmingIf you programm the KINAX 2W2 with a connected powersupply, then the switch on the interface PK610 must be im-perative switched to OFF. If this is ignored, this can lead to thedestruction of the device.Positioning procedure for the KINAX 2W21. Mount the angular position transmitter and mechanically connect it to the objectto be measured. Connect the KINAX 2W2 to the programming device accordingto Fig. 7. Start the 2W2 configuration software. If necessary, configure the devicewith the required measuring range data.2. Place the measuring device in a defined position (prefereably the zero position).3. Select the “Adjustment” menu item under “SERVICE” in the configurationsoftware. In the “Mechanical position” window enter the current angle ofthe measuring device and then select “Adjust”. The measuring device is nowconfigured for the defined angle.7. Electrical connectionsFor connecting the external wires, the transmitter has 2 soldering pins at the back(Fig. 8) or a connecting print with screw terminals (Fig. 9). The soldering postssuffi ce Protection Class IP 00 acc. to IEC 60 529.ProgrammingconnectorSoldering plugsProgrammingconnectorCable-tieclampScrew terminalsFig. 8. Connection with soldering plugs Fig. 9. Connection with screw terminalsNote that, …… the data required to carry out the prescribed measurement mustcorrespond to those marked on the nameplate of the KINAX 2W2(Range, Output, Supply Voltage)!… the total loop resistance connected to the output (receiver plusleads) does not exceed the maximum permissible value Rext. ! See“Measuring output” in Section “5. Technical data” for the maximumvalues of Rext.!… twisted cores must be use for the measured variable input andoutput leads and routed as far away as possible from power cables!In all other respects, observe all local regulations when selecting thetype of electrical cable and installing them!In the case of “Intrinsically safe” explosion-proof versions[Ex ia] IIC, the supplementary information given on the EC-Type-Examination Certificate, the EN 60 079-14 and also local regulationsapplicable to electrical installations in explosion hazard areas mustbe taken into account!Do not excessively heat the soldering posts!Solder using a small pencil bit soldering iron!HR extSolderingplugs–+HR extCable-tieclampScrew terminals–+H = DC power supply H = 12 to 33 V resp. H = 12 to 30 V with Ex versionRext. = External resistanceFig. 10. Connection diagrams for 2-wire connection.8. Setting the beginning and endFine adjustmentThe analog output can be finely adjusted using the 2W2 configuration software.Select the menu item “Adjustment” under “SERVICE”. In the “Analog output”window, the zero position and the end value can now be adjusted.Procedure:1. Put the transmitter into operation and connect the programming device accordingto Fig. 7 (AUX switch on the PK 610 in the OFF position).2. Place the measuring device in the zero position, i.e. in the position in which theKINAX 2W2 should output 4 mA. Adjust with the “ZERO” virtual knob until theoutput is correct. |
Related manuals for Camille Bauer KINAX 2W2
Camille Bauer KINAX 2W2 Operating Instructions Manual
Camille Bauer KINAX 3W2 Operating Instructions Manual
Camille Bauer Kinax WT720 Operating Instructions Manual
Camille Bauer KINAX WT720 Operating Instructions Manual
Camille Bauer KINAX HW730 Operating Instructions Manual
Camille Bauer KINAX WT 717 Operating Instructions Manual
Camille Bauer KINAX WT 717 Operating Instructions Manual
Camille Bauer KINAX N702-INOX Operating Instructions Manual
Camille Bauer KINAX N702-SSI Operating Instructions Manual
Camille Bauer KINAX WT 707-SSI Operating Instructions Manual
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved