Page 19 of 99Power Consumption SpecificationsUnit Configuration Maximum PowerConsumptionActive 75WStandby 65WPower Connection OptionsPower Source and Range Data ConnectionTypeConnectionLengthDC Cable Type /GageExt DC-(40.5 ÷ 60)VDC(Using an RJ-45 to DC cable adaptor)Optical ≤ 75m (247ft) 18AWG76m ÷ 150m(248ft ÷ 493ft)14AWG151m ÷ 300m(494ft ÷ 984ft)12AWGActive PoE Injector Electrical ≤ 100m (328ft) CAT5e (24AWG)Passive PoE Injector for PowerRedundancyOnly for use in non-XPICconfigurations (≤ 57W)Electrical ≤ 100m (328ft) CAT5e (24AWG)PoE Injector Power Input – Standard PoEThe specifications in this section are for the standard PoE Injector units with the followingmarketing models:N000082L022A PTP 820 PoE Injector all outdoor, redundant DCinput, +24VDC supportPoE Injector Power Input – PassivePoEThe specifications in this section are for the passive PoE Injector for use with powerredundancy, with the following marketing model:• N000082L164A PTP 820C INDOOR AC POE INJECTOR, 90WImportant Notes!• The unit must only be installed by service personnel.• The unit must have a permanent connection to protective grounding.• SFP and QSFP ports (Port 3, Port 4, and Port 5) do not provide protection from over-voltages on telecommunication networks for host equipment users.• Disconnect device (circuit breaker) in the building installation:• Shall be readily accessible and incorporated external to the equipment.