561002594 I S S UE 1 M172 V A R I HEATVARIHEAT AW SYSTEM OWNER INSTALLATION MANUAL5.0 VARIHEAT DATA SHEETSpecifications Units AW600AAW600BAW900AAW900BAW1200AAW1200B AW1500BDehumidificationHeat pump dehumidification 30°C/60% RHTotal at 18°C dew point (summer) - if fresh air option fittedTotal at 7°C dew point (winter) - if fresh air option fittedL/hL/hL/h4.65.26.56.57.39.08.59.511.710.511.313.9Heat to airHeat pump heat recovery - Mode A (priority to water)Heat pump heat recovery - Mode B (priority to air)Standard LPHW at 80°C flowUpgraded LPHW at 55°C flowTotal - std. LPHW + Mode A/Mode B heat recoverykWkWkWkWkW05.111.09.411.0/14.007.113.511.513.5/18.6010.024.020.424.0/30.0014.028.023.828.0/36.0Heat to pool waterHeat pump heat recovery - Mode A (priority to water)Heat pump heat recovery - Mode B (priority to air)LPHW @ 80°CLPHW @ 55°CTotal - std. LPHW + Mode A/Mode B heat recoveryFlow rate pool water ± 10%Pressure drop at rated flowMaximum working pressurekWkWkWkWkWL/minm/kPabar5.5018.09.023.5/18.0303.5/34.33.57.4030.015.037.4/30.0323.5/34.33.510.0030.015.040.0/30.0333.5/34.33.512.5040.020.052.5/40.0403.5/34.33.5LPHW dataRecommended min. boiler capacity (standard LPHW at 80°C)Recommended min. boiler capacity (upgraded LPHW at 55°C)Flow rate - standard LPHWFlow rate - upgraded LPHWPressure drop at rated flow rate - standard LPHWPressure drop at rated flow rate - upgraded LPHWLPHW system volumeMaximum working pressurekWkWL/minL/minm/kPam/kPaLbar291925326.3/61.76.3/61.71.66442732446.3/61.76.3/61.71.66543642646.3/61.74.5/44.13.26684452746.3/61.74.9/48.03.26Electrical dataTypical high pressure system with constant flow fanTypical low pressure system with constant flow fanMinimum supply capacity (FLA) 230V/1N/50HzMinimum supply capacity (FLA) 400V/3N/50HzMaximum supply fuse 230V/1N/50HzMaximum supply fuse 400V/3N/50HzkWkWAAAA2.11.817.211.625162.82.422.513.232163.63.12917.842255.14.7-12-16Main fan data - constant flow fansDesign air flow (anemometer @ air on filter, wet evaporator) ± 10%Maximum external static pressure standard LPHWMaximum external static pressure upgraded LPHWDesign running amps - 230V/1N fansDesign running amps - 400V/3N fansFLA - 230V/1N fansFLA - 400V/3N fansm³/hPaPaAAAA20003303203.8-7.6-25002202084.7-7.6-35002901789.3-9.3-4300350320-1.4-4.0Optional fresh air moduleAir flowMaximum external static pressureHeat required for fresh air at -5°Cm³/hPam³/h/kW0-900100150/1.80-900100200/2.30-900100250/2.90-900100300/3.5Optional electric air heater module - (separate power supply)Nominal power (two options per model)Minimum supply capacity (FLA) 230V/1N/50HzMinimum supply capacity (FLA) 400V/3N/50HzMaximum supply fuse 230V/1N/50HzMaximum supply fuse 400V/3N/50HzkWAAAA6 or 1230 or 609 or 1832 or 6310 or 206 or 1230 or 609 or 1832 or 6310 or 2012 or 1860 or -18 or 2763 or -20 or 3012 or 1860 or -18 or 2763 or -20 or 30Compressor dataNominal power consumedNominal RLA - 230V/1N/50HzStarting current 230V/1N/50HzStarting current 230V/1N/50Hz (with soft start)Nominal RLA 400V-3N-50HzStarting current 400V/3N/50HzStarting current 400V/3N/50Hz (with soft start)kWAAAAAA1.58.055263.230142.012.476314.742162.516.6100347.348173.4---10.04825General dataHermetic refrigeration system - gas charge (R407C)Typical weight - unpackedkgkg1.81702.01712.92303.0240