Bosch PRA-FRP3-US Operating Instructions Manual
Operating instructionsRequired: These instructions are to be framed andplaced adjacent to the First responder panel forready reference.Local Service RepresentativeName:Address:Phone:This First responder panel interface is a full‑functionLOC or ACU. The First responder panel has a displayand a sounder that emits distinct condition tones toalert you to alarm or trouble events as they occur. Inconjunction with the display and sounder, status in-dicators provide the following system status inform-ation as described next.OperationNormal operationWhen in normal operation, the First responder panelLOC / ACU shows idle text "All Systems Normal".Fire / MNS (emergency) alarm operationWhen a fire or MNS alarm occurs, and the First re-sponder panel emits a continuous tone: the tonesounds until the silence buzzer button is pressed.The First responder panel will indicate in whichzones the automated message is playing. The FACPwill indicate the source and type of alarm. Acknow-ledging and silencing the alarm must also be donethrough the FACP.Trouble OperationWhen a trouble condition occurs (such as wiring fora Loudspeaker line is cut or AC power fails), theFirst responder panel sounder activates briefly ap-proximately every 5 seconds. The Trouble indicatorlights on the display the trouble log shows the act-ive troubles. Press Silence buzzer to acknowledgethe trouble or navigate in to the trouble log to ac-knowledge the troubles.Silence and ResetTo silence the alarm, use the FACP.To reset the system; first reset the FACP and thenreset the PRAESENSA system using the reset PAbutton on the First responder panel.Overview1. Microphone + key:– Live speech microphone: Active when thespeak indicator (3) is steady on and bypressing the microphone key.– To activate the call: First make a zone / zonegroup (5) selection before pressing the key.2. Indicator:– Trouble indicator: Yellow is trouble.– Mains availability: Green is available/ok.– Battery status: Green is ok.3. Speak indicator:– Flashing: Please wait to speak.– Steady on: Speak now.4. Sounder: Generates (alarm) sounds/tones.5. Zone / Zone group buttons: Selection to startlive announcement/paging.6. Zone status indicators:– Loudspeaker icon Red: Alarm message play-ing in zone.– Loudspeaker icon Blue: Low priority callplaying in zone.– Warning triangle Yellow: Trouble exist in thiszone.7. Transfer of Control: Control indicator:– White button ring lit: The First responderpanel is in control.– White button ring off: Control must be re-quested first, before First responder panelcan be operated.– To Request Control: Press Request Control.– To Deny Control: Press blinking Deny Controlbutton.– To Grant Control: Press blinking Grant Con-trol button.– At ACU: Control can be forced by pressingand holding the button related to the ControlIndicator for two seconds.8. Unlock Annunciator (press and hold): Withinfive seconds of pressing the button, the annunci-ator will be unlocked.9. Trouble Acknowledge: Silences the Troublebuzzers of the PRAESENSA First responder pan-els.Trouble Reset: Reset a Trouble indication after aTrouble condition has been resolved.10. Emergency Acknowledge: Silences the Emer-gency buzzer of the PRAESENSA First responderpanels. It does not silence the audio zones.Emergency Reset: Sets the system to Normaloperation. The alarms and troubles must be re-solved, and reset FACP first.11. Start and stop of alarm messages:– Loudspeaker icon Red on: Alarm messageactive.– Loudspeaker icon Red blinking: Alarm mes-sage active, but possibly not reaching allzones.– White button ring lit: Alarm started fromFRP.12. Control locations button: Shows all control loc-ations, and which location is currently in controlof the system.13. Trouble log button: Access to detailed troublelog.1 | 2 | 3 | 4 |5 | 6 | 7 | 8 | |
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved