Bosch KTS 530 Operator Instructions Manual
Also see for KTS 530: Original instructionsOriginal instructions
Bosch Diagnostics |1 6 8 9 9 7 9 9 8 7 2 006 -09 -2 9Maintenance | K TS 5 30 / K TS 5 40 / K TS 5 7 0 | 234. M a in t e n a n c e4.1 CleaningThe housing of the KTS modules are only to be cleanedusing a soft cloth and a neutral cleaning agent. Do notuse any abrasive cleaning agent or rough cleaning cloths.4.2 MaintenanceThe tab Cu stom er serv ice can be used for performingvarious tests in DDC. A portion of these tests can onlybe performed by customer service.4.3 S pare and w earing partsR eplacement and wear parts only concern partsreceived in the respective delivery.Des cription Ord er Num b erSystem tester KTS 5 3 0 1 6 8 7 0 2 2 4 3 7System tester KTS 5 4 0 1 6 8 7 0 2 2 4 3 6System tester KTS 5 7 0 1 6 8 7 0 2 2 9 9 4Adapter insert 1 6 8 8 0 0 0 3 4 9OBD diagnosis cable 3 m (KTS 5 3 0 )(<) 1 6 8 4 4 6 5 5 5 7OBD diagnosis cable 1 .5 m (KTS 5 4 0 /5 7 0 ) (<) 1 6 8 4 4 6 5 5 5 5Power packPower supply cable (<)1 6 8 7 0 2 2 8 8 91 6 8 4 4 6 1 1 0 6M easuring cable blue (KTS 5 3 0 /5 4 0 ) (<) 1 6 8 4 4 3 0 0 6 6M easuring cable yellow (KTS 5 3 0 /5 4 0 ) (<) 1 6 8 4 4 3 0 0 6 7G round cable black (<) 1 6 8 4 4 3 0 0 6 8M easuring cable red/black (KTS 5 7 0 )(<) 1 6 8 4 4 6 3 2 1 4M easuring cable blue/yellow (KTS 5 7 0 ) (<) 1 6 8 4 4 6 3 5 5 0Test tip red (1 x , with KTS 5 7 0 2 x ) 1 6 8 4 4 8 5 0 3 5Terminal clip black (<) 1 6 8 4 4 8 0 0 2 2Connection cable USB 3 m (<) 1 6 8 4 4 6 5 5 6 2UN I connection cable 4 core (<) 1 6 8 4 4 6 3 5 3 9Case 1 6 8 5 4 3 8 1 4 5M ount parts set 1 6 8 7 0 0 1 8 5 3Bluetooth USB adapter (KTS 5 4 0 /5 7 0 ) 1 6 8 7 0 2 3 3 8 2(<) P a r t s u b je c t to w e a r05 . T e c h n ic a l d a t a5 .1 G eneral d ataProperty V alue/ R angeOperating voltage 7 V DC — 3 0 V DCPower consumption throughvehicle battery or power supply approx . 6 W attDimensions (L x W x H) 1 7 0 x 1 2 0 x 4 0 mmW eight (without connecting cables) 3 2 5 gOperating temperature 0 ° C – 4 0 ° CR elative humidity 9 0 % (at 2 5 ° C)5 .2 Interface protocolsThe following interfaces with respective protocols aresupported for controller diagnosis in conformance withISO 1 5 0 3 1 :ISO 9 1 4 1 -2 (Communications lines K and L)SAE J 1 8 5 0 V PW and SAE J 1 8 5 0 PW M(Communication lines BUS+ and BUS-)CAN ISO 1 1 8 9 8 ISO 1 5 7 6 5 -4 (OBD)(Communication lines CAN -H and CAN -L)CAN Single W ireCAN Low Speed5 .3 Pow er packProperty V alue/ R angeInput voltage 9 0 — 2 6 4 V ACInput frequency 4 7 — 6 3 HzOutput voltage 1 5 VOperating temperature 0 ° C — 4 0 ° C5 .4 Multim eter s pecificationsCH1 zero potential (blue input is not allowed to beconnected with voltage carrying measuring points).Input resistance > 9 0 0 k Ohm.CH2 potential based (black ground inputmust be connected with vehicle ground).Input resistance > 9 0 0 k Ohm.5 .4.1 DC m eas urem ent (CH1 and CH2)Property V alue/ R angeM easurement range 2 0 0 mV — 2 0 0 VPrecision CH1 ± 0 .7 5 % of measurement value,additional ± 0 .2 5 % of measurement rangePrecision CH2 ± 2 % of measurement value,additional ± 0 .5 % of measurement rangeR esolution 1 0 0 μ V — 1 0 0 mV(depending on measuring range)RRRRRRRenhttp://www.obd2be.com/ |
Related manuals for Bosch KTS 530
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved