System Programming ItemsItemNo.Programming Item Range163 Silence Trouble Tones 0 = All trouble tones beep at the controlcenter.1 = Only Fire and 24-Hour trouble tonesbeep at the control center.164 System Inactivity Time(Hours)Enter the number of hours (0-255) that thesystem must be off before it sends theSystem Inactive report.165 System Inactivity Time(Days)Enter the number of days (0-255) that thesystem must be off before it sends theSystem Inactive report.166 System Inactivity Time(Weeks)Enter the number of weeks (0-255) that thesystem must be off before it sends theSystem Inactive report.167 Force Arm/Exit Error 0 = Off-normal points create an exit error atthe end of Exit Delay1 = Off-normal points are force-armed at theend of Exit Delay168 Audio VerificationCommand Set0 = Use SIA Standard Audio Verificationcommands (AV-01-1997.11)1 = Use alternate audio verificationcommand set601 Enable Keyfob Duress 0 = Wireless keyfob does not send a Duressevent1 = Wireless keyfob sends a Duress eventAudio Verification CommandsSIA Standard Audio Verification Commands (Item No. 168 = 0)Phone Button Command[1] Talk to premises.[3] Listen to premises.[6] Listen to premises.[7] Restart 90-second timer.[9][8] Terminate session with call back.[9][9] Terminate session without call back.[0] Listen to all microphones.[#] Cancels first digit of command.Easy Series Control Panel Appendix | en 15Bosch Security Systems, Inc. Quick Start Guide 2014.09 | 01 | F.01U.306.216