10.3.3 Configuring the linked systemCautionAfter installing and wiring the link card package the software configurationhas to take place. This has to be done by use of the software installed onthe Alphadesk central control PC, described in the “Instructions For Use”of the LBB 6511/00.CHAPTER 10Installation InstructionsDECT6000 419922 141 80271 03-07enMaster DCUPinWire colour Slave DCUPin123456789101112131415YellowGreenPurpleGreyPinkRedBlackBlueBlue/redGrey/pinkBrownNot connectedNot connectedNot connectedNot connected876543211514131211109Table 10.2 Link cable connection