Bosch B426 Quick Start Manual
Also see for B426: Setup & troubleshootingInstallation guideQuick start guideInstallation and operationInstallation and operation guide
2 | Bus address settings3 | InstallationAfter you set the address switch for the proper address, install themodule in the enclosure, and then wire it to the control panel and otherdevices.Caution!Remove all power (AC and battery) before making anyconnections. Failure to do so might result in personal injuryand/or equipment damage.3.1 | Mount the module in the enclosureMount the module into the enclosure’s 3-hole mountingpattern using the supplied mounting screws and mountingbracket. Refer to Figure 3.1.31 2Figure 3.1: Mounting the module in the enclosureCallout ― Description1 ― Module with mounting bracket installed2 ― Enclosure3 ― Mounting screws (3)3.3 | Wire to the control panelWhen you wire a B426 to an SDI or SDI2 control panel, you can useeither the module’s terminal strip labeled R, Y, G, B (PWR, A, B, COM)or the module’s interconnect wiring connectors (wire included).Figure 1.1 indicates the location of both the terminal strip and theinterconnect connectors on the module. Run the wires from the moduleto the data bus terminals on the compatible control panel. Refer toFigure 3.2.NOTICE!Use either the terminal strip wiring or interconnect wiringconnector to the control panel. Do not use both. Whenconnecting multiple modules, you can combine terminal stripand interconnect wiring connectors in series.1 | Overview 3.2 | Mount and wire the tamper switchFor instructions on this optional switch (on GV4 Series and B Seriesv2.xx control panels), refer to the Conettix Ethernet CommunicationModule (B426) Installation and Operation Guide (P/N: F01U266226)and the EZTS Cover and Wall Tamper Switch Installation Guide (P/N:F01U003734).Set the address switch per the Table 2.1. If multiple B426 modulesreside on the same system, each B426 module must have a uniqueaddress. Figure 2.1 shows the address switch setting for SDI2 busaddress 1.Callout ― Description1 ― SDI2 control panel. For SDI control panels, wire R, Y, G, B tothe SDI bus.2 ― Interconnect wiring connectors3 ― To Ethernet network4 ― Terminal strip wiring5 ― Interconnect cable (P/N: F01U079745) (included)6 ― Option bus control panelFigure 3.2: Wiring to the control panel (GV4 Series and FPD-70244 | ConfigurationConfigure the B426 using one of the methods described in this sectionfor your control panel type.NOTICE!By default, when connecting a field replacement B426 to anexisting SDI2 or option bus control panel, the panel overridesthe module settings. To keep custom module settings whenyou connect a module to a configured control panel, you mustdisable Panel Programming using web-based configuration,prior to connecting to the SDI2 or option bus.When connected to a non-default SDI2 or option bus control panel, thecontrol panel automatically configures a connected module.1. Set the address switch to the correct address for the control panel(SDI2 control panels use address 1 or 2, option control panels useaddresses 134 or 250).2. Connect the module to the control panel bus and apply power.3. Program the control panel communication settings using RPS forSDI2 control panel, A-Link for option control panel, or the keypad.NOTICE!Before proceeding, ensure that the web browser is notconfigured to use a proxy server. Refer to the browser’sonline help for instructions on disabling proxy service.4.1 | PnP for SDI2 or option bus control panel4.2 | PnP for SDI or option bus control panelsWhen installing under the following conditions, the B426 needs nofurther configuration:– DHCP is available on your network.– AES encryption is not required.– Default B426 port settings (UDP on Port 7700) are permitted bythe network administrator.4.3 | Web-based configurationFor installations requiring non-default configuration, use the B426 web-based configuration pages.To use the B426 configuration pages, you need the module’s IP addressor hostname.– The default hostname for the module is the letter B followedby the last six alpha-numeric digits of its MAC address (forexample, B3F603F).– Locate the IP address in the table on the DHCP server(networked modules).– To use Auto IP, directly connect from your PC to the B426.Within 60 seconds, the B426 temporarily assumes address169.254.1.1 for configuration. (Refer to the Conettix EthernetCommunication Module Installation and Operation Guide formore information on using these methods.)Logging into web-based configuration (B426 Configuration Pages):1. Open an internet browser (Microsoft Internet Explorer or MozillaFirefox) and type in the B426’s IP address. The B426’s login pageopens.2. Enter the password (the default is B42V2) and click Login. TheDevice Information home page opens.3. Browse to the desired settings page and configure theparameters.4. Click OK and then click Save & Execute to save and apply allchanges to the device.control panel shown)NOTICE!Option bus control panels support AMAX 2100/ 3000/ 4000firmware version v1.5 or higher only.NOTICE!The module reads the address switch setting only duringpower up. If you change the switch after you apply powerto the module, you must cycle the power to the module inorder for the new setting to be enabled.One address switch determines the address for the B426 ConettixEthernet Communication Module. The control panel uses the addressfor communications. Use a slotted screwdriver to set the addressswitch.Figure 2.1: Address switchTable 2.1: Address switch settingsControlpanelsSwitchpositionControlpaneladdressBus type FunctionB9512G/B8512G,B6512/B5512/B4512/B3512,GV4, Solution2000/30001 1 SDI2 Automation,RemoteProgramming,orReportingB9512G/B8512G, GV4,Solution,2000/30002 2GV4,GV3,GV2, D9412G/D7412G/D7212G v6.3or higher3 80 SDI Automation4 88 Remoteprogramming orReportingGV4 and GV3 5 92FPD-7024v1.06+,DS7240V2,DS7220V2,Easy Series,V3+, CMSSeries, AMAXSeries6 134 OptionDS7400Xi 7 13DS7400Xi 8 14 ReportingFPD-7024,CMS Series,AMAX Series9 250 Remoteprogramming orReportingThe B426 Ethernet Communication Module is a four-wire powered SDI,SDI2, or option bus device that provides two-way communication withcompatible control panels over IPv4 or IPv6 Ethernet networks.The B426 on-board switch determines the bus address of the device.Configuration of the B426 is performed through the B426 configurationweb pages. On SDI2 control panels, configuration can also be done onthe keypad or through Remote Programming Software (RPS).Figure 1.1: Board overviewCallout ― Description1 ― Ethernet RJ-45 port2 ― Yellow LINK LED3 ― Green 100MB LED4 ― Address switch5 ― Heartbeat LED (blue)6 ― TX and RX LEDs7 ― Terminal strip(to control panel or additional modules)8 ― Interconnect wiring connectors(to control panel or additional modules)9 ― Tamper switch connector |
Related manuals for Bosch B426
Bosch B426 Quick Start Manual
Bosch C900V2 Quick Start Manual
Bosch CR 20 RF Quick Start Manual
Bosch CONNECT RLDP-V Quick Start Manual
Bosch Rexroth BVD 52 Series Quick Start Manual
Bosch B426 Installation Manual
Bosch B426 Installation Manual
Bosch Security Systems Blue Line A1-CC Quick Start Manual
Bosch D9127U Quick Installation Manual
Bosch VCU Manual
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved