How to display faults and tampers via a master keypadIn a master keypad the system faults and tampers are displayed directly. After an area isselected, the area-specific faults and tampers are displayed.How to display faults and tampers via a LED/LCD keypadTo display faults and tampers via a LED/LCD keypad, perform the following steps:1. Enter your code + [2] [1] and press [#].The system beeps twice. The FAULT indicator is extinguished and the STAY and AWAYindicators flash. One of the number indicators is lit. Example: 2.2. Enter the number that is lit in the system. Example: 2.One of the number indicators is lit. Example: 1.3. Repeat step 2 until there is no number lit anymore.4. Refer to the table Types of fault or tamper conditions for a description of the fault ortemper. The consecutively lit number indicators correspond to fault or tamper types.Example: 2 – 1, which indicates a panel AC failure.5. If necessary press [0] to return to step 2.6. Press [#] to exit.P The STAY and AWAY indicators are extinguished and the FAULT indicator is lit.For an overview of the possible faults and tampers and how to solve them, see Trouble FaultInquiry, page 140.FW VersionThis option displays the current firmware version.System Factory DefaultThe system can be reset to the factory default settings either via software or via hardware.How to Reset the System to the Factory Default Settings via SoftwareDefault PanelThis option resets the system to the factory settings.4 Select DEFAULT PANEL YES if you really want to reset the system or select DEFAULTPANEL NO if you don’t want to reset the system.P All programming parameters and recorded voice messages are reset to factory default.Default only with InstallerThis option enables/disables the possibility to reset the system via hardware. If this option isenabled, the system can not be reset via hardware any more.How to Reset the System to the Factory Default Settings via HardwareThe system can be reset to factory default settings with the ‘resetting to factory default’ padsat the top on the printed circuit board on the main board of the AMAX panel if this possibilityis enabled in the software.1. Disconnect the AC power supply and the backup battery.2. Short-circuit the ‘resetting to factory default’ pads.3. Power up the system.Quick flash of the red LED indicator on the printed circuit board of the AMAX panelindicates that the factory default is reset.P All programming parameters and recorded voice messages are reset to factory defaultimmediately after releasing the short-circuited bonding pads.7.5.370 en | Settings AMAX 2100 / 3000 / 40002014.11 | 02 | F.01U.267.112 Installation Guide Bosch Sicherheitsysteme GmbH