13Manuale d’installazione e d’uso1. INSTALLATIONMINIMUM ADJUSTMENT:Remove the knob and the front cover.To adjust to minimum, adjust the screw (Ref. 1): loosento increase the flame and tighten to decrease the flame.For liquid petroleum gas, turn the screw to minimum.When the flame is in the minimum position, check that itis stable along the whole burner surface and check thatwhen the flame is increased from minimum to maximumthe flame does not go out and that the nozzle does notcatch fire.Once the gas conversion operations have been completed, check the dismantled parts for leaks using soapy wateror foam products. DO NOT SEARCH FOR LEAKS WITH NAKED LIGHTS.Before delivering the appliance to the user:• check that it operates correctly,• instruct the user on how to use it.2. OPERATING INSTRUCTIONSThe appliance must be used only for the purpose for which it was designed. Any other use is improper. Duringoperation, supervise the appliance.Before starting up the appliance for the first time, unpack it.• Check that no obstacle inside the appliance obstructs the air flow required for combustion and check thatthe premises are sufficiently ventilated.• Check the efficiency of the devices for evacuating cooking fumes (extraction hood, discharge collector,etc).• Use gloves to work on the appliance.The control knobs (Fig.5) of the burner taps have 3positions:2.1 Commissioning2.2 Settingshutmaximum flameminimum flameEN