6-30 Chapter 6: RAID configurationSelect a destination disk with the same size as the original hard disk.[ DEGRADED VOLUME DETECTED ][↑↓]-Previous/Next [ENTER]-Select [ESC]-Exit"Degraded" volume and disk available for rebuilding detected. Selectinga disk initiates a rebuild. Rebuild completes in the operating system.Select the port of destination disk for rebuilding (ESC to exit):Port Drive Model Serial # SizeX XXXXXXXXXXX XXXXXXXX XX.XGB6.3.7 Rebuilding the RAIDThis option is only for the RAID 1, RAID 5 and RAID 10 sets.Rebuilding the RAID with other non-RAID diskIf any of the SATA hard disk drives included in the RAID 1 array failed, the systemdisplays the status of the RAID volume as “Degraded” during POST. You canrebuild the RAID array with other installed non-RAID disks.To rebuild the RAID with other non-RAID disk:1. At the prompt, press + to enter the Intel Matrix Storage Manageroption ROM utility.2. If there is a non-RAID SATA Hard Disk available, the utility will prompt torebuild the RAID. Press , and then use up/down arrow keys to selectthe destination disk or press to exit.6.3.6 Exiting the Intel® Matrix Storage ManagerTo exit the utility1. From the utility main menu, select 5. Exit, and then press . Thefollowing warning message appears.2. Press to exit or press to return to the utility main menu.Are you sure you want to exit? (Y/N):[ CONFIRM EXIT ]