© Agrowtek Inc. | www.agrowtek.com | Technology to Help You Grow™1 © Agrowtek Inc. | www.agrowtek.com | Technology to Help You Grow™Technology to Help You GrowAGROWtEKPower 24Vdc, ~5WMax Cable Distance 1000ftAspirator 6cfm Fan with Foam FilterTemperature Range -20 - 60°CTemperature Accuracy ±0.2°C typical±0.4°C maximumHumidity Range 0-100% RH (non condensing)80% RH Max OperatingHumidity Accuracy ±2% 0-80% typical±4% maximumLight Irradiance Range 0 - 1000W/m2Light Accuracy ±10%CO2 Range 0-40,000ppmCO2 Accuracy ±50ppm + 3% of reading4-20mA DAC Resolution 12 bit, 0.005mAProtocols Supported GrowNET or MODBUSSpecificationsClimate Sensor & Data Logger with LCD DisplayContentsFeatures 2Warnings & Notices 3Condensate Loop 3Installation Instructions 4Cable Connector Seal Boot 4Maintenance & Service 5Cleaning 5Fan Filter 5CO2 ppm Sensor Upgrade 6LCD Menu Operation 7High / Low History 7Graphing 7Main Menu 8Alarms Menu 8Alarms Configuration 8Alarm Buzzer 9Calibration Menu 9Temperature or Humidity Calibration 9CO2 Calibration 10Clear Calibration 10Advanced Calibration 11Analog Output Calibration 11Setup Menu 12Time / Date 12Units 12Logging Interval 13COMM Mode 13Device Address 14Manufacturing Info 14Display Back Light Timer 14Connection to GrowControl™ GCX 15GrowNET™ Hubs 15Connection to USB AgrowLINK 16Connection to 4-20mA Outputs 16Connection to MODBUS RTU 17Serial Speed & Format 17Supported Commands 18Register Types 18Sensor Value Registers 18Toggle Units Register 18Calibration Registers 18MODBUS Holding Registers 19Storage and Disposal 20Warranty 20INSTRUCTION MANUALSXC+KEEP THESE INSTRUCTIONS REV 5/23