Before You BeginYou’ll need the following:• Time Q +Plus Terminal• A slotted tip screwdriverFollow the setup instructions on this QuickStart sheet.Time Q +Plus Quick StartEstablishcommunicationsUnpack your terminalwww.acroprint.comInstall PC Software1. Start Windows.2. Choose Start > Settings > Control Panel.3. Double-click the Add/Remove ProgramsProperties option.4. At the dialog screen choose the Install/Uninstall tab.5. Click Install. At the dialog screen “InstallProgram from Floppy Disk or CD-ROM”insert the 3½” Time and Attendance PCSoftware floppy disk into the drive andclick Next. Follow the on-screeninstructions.6. Command line: A:\Setup.exe, Click“Finish.”7. Destination directory: C:\Time andAttendance, click “OK” if you don’t want tochange.8. When setup has installed the software,click on “OK.”9. The “Read me” file may be printed, read atthe monitor, or closed.Remove the accessdoorThe bracket may be reversed for wallmounting. The terminal is shipped with thebracket in the desk mounting position. Securethe bracket to the wall with the four screwssupplied. Mount the top of the bracket 54" fromthe floor. Slide the Time Q +Plus onto thebracket.Wall mounting1. Make sure power is off at both the timeclock terminal and the PC, and the accessdoor on the terminal is removed.2. Using the cable supplied with the terminal(50') connect the RJ-11 modularconnector to theRS-232 port onthe lower leftcorner.3. Connect theother end of theRJ-11 to the 9-pinadaptor suppliedwith the system. Ifyour computer has a 25-pin serial port youwill need a 9-pin to 25-pin adaptoravailable at most computer stores.4. Connect the adaptor to the RS-232 (9-pin)serial port located on the back of yourcomputer.Connect Time Q +Plus to IBM compatible PC1. In most cases the software willautomatically locate the PC serial port. Ifthe software does not locate the serialcommunications port:a. From the PC, start the Time andAttendance program.b. Select the communications icon, thenselect the correct communications portand baud rate.Note: the baud rate on the PC must match thebaud rate set on the Time Q +Plus. Thedefault setting on the terminal is 9600. Thebaud rate may be changed at the terminalby using the Supervisor's badge.Plug in power cordCentronics 36 Male Plug(connect to printer)Parallel Printer ConnectionThe Time Q +Plus terminalmay be connected directly toan IBM® compatible printer.Reports can be printedwithout a PC.DB25 Male Plug(connect to terminal)Reattach access door. 9 pin adaptorPlug the Centronics 36 male pluginto the parallel port on the back ofthe printer.Using the slotted tip screwdriver,remove the access door.Time Q Plus no for lang.p65 1/22/01, 12:39 PM1