31j) Measurement and/or constantly monitoring of 20 most important parameters of the amplifier viaRCU and/or PC.k) Adjustable RCU Beep and Contrast.7-3. Storage and ShipmentC A U T I O NShould you need to transport the amplifier, use the original packing as describedbelow.First pull the mains plug out of the mains outlet, afterwards disconnect all cables from the rear panel ofthe amplifier (remove the ground connection last) and wait 30 minutes. Then remove the mains powertransformer, observing the requirements of S.2-3, but in reverse order. Pack the RCU in the box providedfor it, and put it in the amplifier in the place of the mains transformer. Screw in the transport board tothe transformer using the four shipping screws, pack the four shorter (mounting) bolts in the polyethyleneenvelope. Finally mount the cover and pack the amplifier and transformer in their original cartons.a) Storage environments: the amplifier can be kept packed in dry and ventilated unheated premiseswithout chemically active substances (acids, alkalies etc.) in the following climatic environment:z temperature range: -40 to +70 degs.Celsius;z humidity: up to 75% @ +35 degs.Celsius.b) Shipping Size and Weight:z W390mm x D330mm x H350mm, 19kg - Transformer carton;z W630mm x D590mm x H310mm, 19kg - Amplifier carton.c) Shipping environments: all types of transportation, including aircraft baggage section up to 12000meters above sea level.