Mounting and Wiring the Control2-19Audio Alarm Verification Connections (AAV, “Listen-In”)Using the UVS System with UVCM ModuleRefer to the connection diagrams below. One diagram shows connections when a 4286 Phone Moduleis used, the other shows connections when the 4286 is not used.Connections use one of the on-board triggers.UL UL installations using the AAV feature must use the ADEMCO UVCM module (part of the ADEMCO UVSsystem).Suggested AAV Module: ADEMCO UVSNotes• Set field *91 for AAV and program the appropriate output (output 17 or 18) using *80 Menu mode:select zone type “60” and output action 1 (close for 2 seconds).• For voice session monitoring, connect a zone to module terminals 6 & 7, and program the zone aszone type 81 (*56 Menu mode).E.g., Using output 18 for the trigger, program an output function in *80 Menu mode as:ZT = 60, P = 0, Action = 1, Device = 18ON ON1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 81 2 3 4 5 6 7 8 9 10 11 29 30 31 32 33 34NOTE:REFER TO UVCM MODULEINSTRUCTIONS FORCONNECTIONS TO AUDIOSPEAKERS AND MICROPHONE.UVCMMODULEZONETERMINALSEARTHGROUNDRED (R)GREEN (T)GREY (R)BROWN (T)TRIGGERCONNECTOROUTPUT 18EOLRINGTIPOPTIONALMONITORING ZONECONNECTION(USE ZONE TYPE 81)FALLING VOICE TRIGGND+12VDC INSWITCHBANK 2SWITCHBANK 1SWITCH BANK 2SWITCH BANK 1AUXILIARYAUDIO LEVELADJUSTMENTTRIM POTaav_uvcm-003-V0CONTROLINCOMINGPHONE LINETOPREMISESHANDSET51 = ON2 = ON3 = OFF4 = ON5 = ON6 = ON7 = ON8 = ON1 = OFF2 = OFF3 = OFF4 = OFF5 = OFF6 = OFF7 = OFF8 = ON23 24 25+12VDCGND4 5 21 22RJ31XFigure 15. Connection of AAV Unit When Not Using a 4286 Phone Module