Service TestJanuary 2012 16500030©2012 ACP, Inc.11To Enter Service Test Mode, oven door must be closed.NOTE: Unit must be in OFF conditionorINITIAL power up mode.NOTE: Pads will not beep when accessing Service Test Mode.To EXIT Service Test Mode press STOP/RESET pad.MC units DQ22HSI and KFC2 RC unitsREG MENUMISCMode Name Service ModeEntry Pressing Hidden Pad, 1, 3, 5, 7, 9 while in the ready mode:FunctionalDescriptionMain Service Mode MenuDisplayS e r v i c e M o d e6 0 H Z 2 0 8 VPad 1 Mode Name Service Pad 1Entry Pressing Pad 1 while in Service ModeFunctionalDescriptionDisplayPad 2 Mode Name Service Pad 2Entry Pressing Pad 2 while in Service ModeFunctionalDescriptionMagnetron #1 shall be toggled. When on, it shall run for 62 seconds.DisplayM a g n e t r o n # 1 : O N0 0 : 4 5 A m p s : 1 2Magnetron #2 shall be toggled. When on, it shall run for 62 seconds.M a g n e t r o n # 2 : O N0 0 : 4 5 A m p s : 1 2Note: Not applicable on two magnetron models:Pad 3 Mode Name Service Pad 3Entry Pressing Pad 3 while in Service ModeFunctionalDescriptionDisplayMagnetron #3 shall be toggled. When on, it shall run for 62 seconds.M a g n e t r o n # 3 : O N0 0 : 4 5 A m p s : 1 2