prepArAtIons, InstAllAtIon And tAkIng Into operAtIon8MODEL GRID CONNECTION MODEL VARIANT3W22A2 230 / 400 V50 Hz 32 AFour-wire system with three outer conductors andneutral conductor; two integrated charging socketsaccording to IEC 62196-2 Type 2 for the separatelyavailable Mode 3 charging cable; access control viaRFID; internal Type A RCCB; internal DC fault currentdetection; max. charging output up to 2x 11 kWWARNING!The information and technical specifications contained in this manual re-late exclusively to the model variants mentioned in these instructionsand must not be transferred to other wallbox models. These variants aredelivered with specific instruction manuals where necessary.Should your wallbox variant not be described in this manual, please con-tact ABL technical support: Do not under any circumstances install thewallbox in this case, as this could lead to damage to the wallbox, to injuryand/or death.General requirements of the installation siteYour ABL Wallbox is an electrical device and is therefore subject to particular require-ments for indoor and outdoor installation. In selecting the installation site, you mustconsider the following points:• Consider all local regulations for electrical installations,fire protection and accident prevention.• The wallbox must be installed where it is freely acces-sible to all authorized users.• A parking spot must also be planned for in front of thewallbox so that the vehicle can at all times be reachedwith the integrated or with an external charging cable.• The recommended installation height is 120 to 140 cmfrom the floor to the lower edge of the housing. Thisrecommendation may be adjusted upwards or down-wards depending on local conditions.• Sufficient air circulation must be ensured at the installa-tion site so that the wallbox is cooled during operation:Always observe the allowed operating temperatures(see “Technical specifications” on page 16).• The mounting area must have an even surface that pro-vides sufficient stability for installing the wallbox.• The required mounting area for the ABL Wallbox is at least 512 x 429 mm (H x W). Allof the mounting plate of the wallbox must be in contact with the mounting surface.120 to140 cm