34 Portable Capacitance Meter CB-2000 — User´s Guide | ABB Power Capacitors5. PC application5.3 Measurement data opened with Microsoft ExcelCB-2000 measurement data is saved as tab-delimited text, which can be opened with Microsoft Excelor any other spreadsheet program.Example of downloaded file, when opened with Microsoft Excel.The time stamp and temperature reading belong to the latest measurement.Column Description InputA. Serial no. Maximum 10 charactersB. Time stamp of latest measurement YYYY-MM-DD hh:mm:ssC. Reference measurement Digits and decimal separatorD. Latest measurement Digits and decimal separatorE-H. Previous measurements Digits and decimal separatorI. Temperature of latest measurement Digits onlyThe same file can be uploaded to a CB-2000 unit, with the serial no. column and reference column beingespecially important. The reference column can contain values from the routine test or the latest measure-ment. The file must be saved in tab-delimited text format to be read by the CB-2000 PC application.