ABB C50 Product Manual
ABB LimitedMeasurement & AnalyticsHoward Road, St. NeotsCambridgeshire, PE19 8EUUKTel: +44 (0)1480 475 321Fax: +44 (0)1480 217 948Email: instrumentation@gb.abb.com45 x 45mm+0.5 –0.0CAUTION: Turn off all power. Remove instrument by gripping the sides of thefront panel and pulling the instrument out of its housing. Note its orientation.Panel-MountingThe mounting panel must be rigid and may be up to 6.0mm(0.25 inches) thick. The cut-out required for the instrument isshown on the right. Instruments may be mounted side-by-sidein a multiple installation for which the cut-out width (for ninstruments) is (48n-4)mm or (1.89n-0.16)inches.Rear Terminal WiringNote: At first power-up the message is displayed, asdescribed in section 8 of this manual. Access to other menus is denieduntil configuration mode is completedSelect mode is used to access the configuration and operation menu functions.It can be accessed at any time by holding down and pressing .Once in select mode, press or to select the required mode. An unlock code isrequired to prevent unauthorised entry to Configuration, Setup & Automatic Tuning modes.Press or to enter the correct code number, then press to proceed.Mode UpperDisplayLowerDisplayDescription Default UnlockCodesOperator Normal instrument operation. NoneSet Up Tailor settings to the application. Configuration Configures the instrument for use. Product Info Check manufacturing information. NoneAuto-Tuning Invoke Pre-Tune or Self-Tune. Note: The instrument will always return automatically to Operator mode if there is nokey activity for 2 minutes.First select Configuration mode from Select mode (refer to section 2).Press to scroll through the parameters, then press or to set the required value.To accept a change must be pressed, otherwise parameter will revert to previous value.To exit from Configuration mode, hold down and press , to return to Select mode.Note: Parameters displayed depends on how instrument has been configured.Parameters marked * are repeated in Setup Mode.Parameter LowerDisplayUpperDisplayAdjustment range DefaultInput Range/Type See following table for possible codes J T/CScale RangeUpper Limit Scale Range Lower Limit +100 to Range Max Range max(Lin=1000)Scale RangeLower Limit Range Min. to Scale Range Upper Limit -100 Range min(Linear=0)Decimal pointposition 0=XXXX, 1=XXX.X, 2=XX.XX, 3=X.XXX(non-temperature ranges only)1 Primary (heat) onlyControl Type Primary & Secondary (heat/cool) Reverse ActingPrimary OutputControl Action Direct Acting Process High Alarm Process Low Alarm Deviation Alarm Band AlarmAlarm 1Type No alarmHigh Alm 1 value* Range Max.Low Alm 1 value* Range Min. to Range Maxin display units Range Min.Band Alm 1 value* 1 LSD to span from setpoint in display units Dev. Alm 1 value* +/- Span from setpoint in display units Alm 1 Hysteresis* 1 LSD to full span in display units Process High Alarm Process Low Alarm Deviation Alarm Band AlarmAlarm 2 Type No alarmHigh Alm 2 value* Range Max.Low Alm 2 value* Range Min. to Range Maxin display units Range Min.Band Alm 2 value* 1 LSD to span from setpoint in display units Dev. Alm 2 Value* +/- Span from setpoint in display units Alm 2 Hysteresis* 1 LSD to full span in display units Loop Alarm (disabled) or (enabled) Loop Alarm Time* 1 sec to 99 mins. 59secs(only applies if primary proportional band = 0) . No alarms Inhibited Alarm 1 inhibited Alarm 2 inhibitedAlarm Inhibit Alarm 1 and alarm 2 inhibitedParameter LowerDisplayUpperDisplayAdjustment range Default Primary (Heat) Power Secondary (Cool) Power Alarm 1, Direct Alarm 1, Reverse Alarm 2, Direct Alarm 2, Reverse Loop Alarm, Direct Loop Alarm, Reverse Logical Alarm 1 OR 2, Direct Logical Alarm 1 OR 2, Reverse Logical Alarm 1 AND 2, DirectOutput 1 Usage Logical Alarm 1 AND 2, Reverse Primary (Heat) Power Secondary (Cool) Power Alarm 1, Direct Alarm 1, Reverse Alarm 2, Direct Alarm 2, Reverse Loop Alarm, Direct Loop Alarm, Reverse Logical Alarm 1 OR 2, Direct Logical Alarm 1 OR 2, Reverse Logical Alarm 1 AND 2, DirectOutput 2 Usage Logical Alarm 1 AND 2, ReverseDisplay Strategy , , , , or (refer to section 7) Config Lock Code 0 to 9999 Input Ranges and Types(See Configuration Mode Parameter )Code Input Type & Range Code Input Type & Range Code Input Type & RangebCbCbCbC B: 100 – 1824 ºC LLLL.CCCC L: 0.0 – 537.7 ºCbFbFbFbF B: 211 – 3315 ºF LLLL.FFFF L: 32.0 – 999.9 ºF P24FP24FP24FP24F PtRh20% vs 40%:32 – 3362 ºFCCCCCCCC C: 0 – 2320 ºC NCNCNCNC N: 0 – 1399 ºC PTCPTCPTCPTC Pt100: -199 – 800 ºCCFCFCFCF C: 32 – 4208 ºF NFNFNFNF N: 32 – 2551 ºF PtFPtFPtFPtF Pt100: -328 – 1472 ºFJCJCJCJC J: -200 – 1200 ºC rCrCrCrC R: 0 – 1759 ºC PtPtPtPt.CCCC Pt100: -128.8 – 537.7 ºCJFJFJFJF J: -328 – 2192 ºF rFrFrFrF R: 32 – 3198 ºF PtPtPtPt.FFFF Pt100: -199.9 – 999.9 ºFjjjj.CCCC J: -128.8 – 537.7 ºC SCSCSCSC S: 0 – 1762 ºC 0 – 20 mA DCjjjj.FFFF J: -199.9 – 999.9 ºF SFSFSFSF S: 32 – 3204 ºF 4 – 20 mA DCKCKCKCKC K: -240 – 1373 ºC tCtCtCtC T: -240 – 400 ºC 0 – 50 mV DCKFKFKFKF K: -400 – 2503 ºF tFtFtFtF T: -400 – 752 ºF 10 – 50 mV DCkkkk.CCCC K: -128.8 – 537.7 ºC t.Ct.Ct.Ct.C T: -128.8 – 400.0 ºC 0 – 5 V DCKKKK.FFFF K: -199.9 – 999.9 ºF t.Ft.Ft.Ft.F T: -199.9 – 752.0 ºF 1 – 5 V DCLCLCLCLC L: 0 – 762 ºC 0 – 10 V DCLFLFLFLF L: 32 – 1403 ºF P24CP24CP24CP24C PtRh20% vs 40%:0 – 1850 ºC 2 – 10 V DCCAUTION: Do not remove the panel gasket; it is a seal against dust andmoisture.CAUTION: Installation and configuration should be performed only bypersonnel who are technically competent to do so. Local Regulations regardingelectrical installation & safety must be observed.1. INSTALLATIONC50 1/16-DIN PROCESS CONTROLLERCONCISE PRODUCT MANUAL – IM/C50Hold instrument firmly in position(apply pressure to bezel only)Mounting PanelInstrument HousingRatchetsGasketSlide mounting clamp over theinstrument housing towards rear faceof mounting panel until the tonguesengage in ratchets and instrument isclamped in position.2. SELECT MODE3. CONFIGURATION MODECAUTION: Check information label onhousing for correct operating voltagebefore connecting supply to Power InputFuse: 100 – 240V ac – 1amp anti-surgeNOTE: Option 2 is only available onmodel C50K-2110-00.USE COPPER CONDUCTORS(EXCEPT FOR T/C INPUT)Single Strand wire gauge:Max 1.2mm (18SWG) |
Related manuals for ABB C50
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved