- Contents of this chapter
- General safety in installation, start-up and maintenance
- Electrical safety in installation, start-up and maintenance
- Optical components
- Additional instructions for permanent magnet motor drives
- Quick installation and commissioning flowchart
- Terms and abbreviations
- Related documents
- Layout
- Frame size R3
- Frame R4...R8
- External control connecting terminal, Frame size R0...R2
- External control connecting terminal, Frame size R3...R5
- External control connection terminals, frames R6...R8
- Control panel
- Type designation label
- Locations of the labels on the drive
- Type designation key
- Checking the installation site
- Required tools
- Unpacking and examining delivery, frames R0...R2
- Unpacking and examining delivery, frames R5
- Unpacking and examining delivery, frames R6...R8
- Installing the drive
- Installing the drive vertically, frame size R3...R4
- Installing the drive vertically, frames size R5...R8
- Installing the drive vertically side by side
- Other regions
- Alternative power cable types
- Recommended power cable types
- Conduit
- Signals in separate cables
- Routing the cables
- General guidelines, North America
- Continuous motor cable shield or enclosure for equipment on the motor cable
- Protecting the motor against thermal overload
- Using a contactor between the drive and the motor
- Switching the motor power supply from drive to direct-on-line
- Switching the motor power supply from direct-on-line to drive
- Input power cable
- Ground-to-phase varistor
- Frames R4...R8
- Connecting the power cables
- Connection procedure: frames R0...R2
- Finalization
- Connection procedure, frames R3...R4
- Note
- Connection procedure, frames R5...R8
- DC connection
- Default control connections of ABB standard macro
- Notes
- NPN configuration for digital inputs
- Connection examples of two-wire and three-wire sensors
- DI5 as frequency input
- Control cable connection procedure R0...R8
- R0...R2
- R3...R5
- R6...R8
- Front option slot 1
- To remove a front option
- Reinstalling side plates and covers, frames size R5...R8
- Recommended annual maintenance actions by the user
- Heatsink
- Replacing the cooling fan, frames size R0...R4
- Replacing the main cooling fan, frames size R6...R8
- Replacing the auxiliary cooling fan, frames R6...R8
- Capacitors
- LEDs
- Definitions
- Derating
- Switching frequency derating
- Altitude derating
- gG fuses
- gR fuses
- DC fuses
- Circuit breakers
- Dimensions, weights and free space requirements
- Thermal losses, cooling data and noise
- Terminal and lead-through data for the power cables
- Terminal and lead-through data for the control cables
- Electrical power network specification
- EMC compatibility and motor cable length
- Control connection data
- Auxiliary circuit power consumption
- Efficiency
- For R3...R8
- Materials
- CE marking
- Category C1
- Category C4
- Frame R0, IP20
- Frame R1, IP20
- Frame R3, IP20
- Frame R4, IP20
- Frame R5, IP20
- Frame R6, IP20
- Frame R7, IP20
- Frame R8, IP20
- Compliance with the European Machinery Directive
- Wiring
- Wiring examples (R0...R2)
- Connection principle (R3...R8)
- Wiring examples (R3...R8)
- Cable types and lengths
- Operation principle
- Start-up including acceptance test
- Maintenance
- Fault tracing
- Safety data
- Abbreviations
- Electrical installation
- Start-up
- Dimensions
|
Replacement fans are available from the manufacturer. Do not use other than specifiedspare parts.■ Replacing the cooling fan, frames size R0…R4WARNING!Obey the instructions in chapter Safety instructions (page 11). Ignoring theinstructions can cause physical injury or death, or damage to the equipment.1. Stop the drive and disconnect it from the power line. Wait for 5 minutes and then makesure by measuring that there is no voltage. See section Electrical safetyprecautions (page 14) before you start the work.2. Lever the fan assembly off the drive frames with for example a screwdriver (2a), andpull out the fan assembly (2b).3. Unplug fan power supply wires from the drive.4. Install the fan assembly in reverse order.increases the life span of the fan.Replacement fans are available from the manufacturer. Do not use other thanspecified spare parts. Replacing the cooling fan, frames size R0…R4WARNING! Obey the instructions in chapter 11 on page Safety instructions.Ignoring the instructions can cause physical injury or death, or damage to theequipment.1. Stop the drive and disconnect it from the power line. Wait for 5 minutes and thenmake sure by measuring that there is no voltage. See section 14 on pagePrecautions before electrical work before you start the work.2. Lever the fan assembly off the drive frames with for example a screwdriver (2a),and pull out the fan assembly (2b).3. Unplug fan power supply wires from the drive.4. Install the fan assembly in reverse order.2a05acresR0...R2 R3...R42b2bR3...R4R0...R2■ Replacing the main cooling fan, frame R5WARNING!Obey the instructions in chapter Safety instructions (page 11). Ignoring theinstructions can cause physical injury or death, or damage to the equipment.1. Stop the drive and disconnect it from the power line. Wait for 5 minutes and then makesure by measuring that there is no voltage. See section Electrical safetyprecautions (page 14) before you start the work.2. Lift the fan assembly upwards from the front edge (2a) and remove the assembly (2b).3. Unplug fan power supply wires from the drive.104 Maintenance and hardware diagnostics