ABB Welcome®— 9 —4.3 Programming modestart1. Long press “Prog” button for 3seconds to enter programming mode2. Choose cameras to set by dip switchV1/V2/V3/V44. Set the working mode by R1Mode=1, Camera interface works as an independent outdoor station.Mode=2, Camera interface works associated with outdoor station.Mode=3, Camera interface works associated with guard unit.Mode=4, Camera interface works associated with indoor station.3. Assign the address of the camerainterface by R35. Short-press "Prog" button to save current setting.6. Set the address of the associateddevice by these three rotary switchesAddress=R1*100+R2*10+R3continue toprogram8. Long press “Prog” button 3 secondsto exit programming mode.End7. Short-press "Prog" button to savecurrent setting.NYR1 R2 R3