4titude a4S Quick User Manual
4titude Ltd. • The North Barn • Surrey Hills Business Park • Damphurst Lane • Wotton • Surrey • RH5 6QTT: +44 (0)1306 884885 • F: +44 (0)1306 884886 • E: info@4ti.co.uk • www.4ti.co.uk4ti-FL-0010 Quick User Guide a4S Automatic Heat Sealer VA en1/0/25/07.2015 OPAutomatic Heat Sealer a4S Quick User Guide • Version ANote: This quick user guide is not a replacement for the a4S Operation Manual which must be read before using the heat sealerfor the first time. All users must know and observe all safety instructions as detailed in the operation manual.Important!Shipping BracketThe a4S is shipped with a transportation bracket to prevent the plate shuttle moving during shipping. It is essential that thisbracket is removed before the unit is powered up for the first time.Sensor Protection ScrewTo protect the rear foil sensor during transportation, the a4S is shipped with a protective screw highlighted with a white washer,inserted into the rear of the instrument. Before the unit is switched on, please make sure that the screw is removed from theinstrument and retained with the other transportation packaging.Please also refer to the a4S Operation Manual.Operation of the a4S Automatic Heat Sealer1. Connect the power cord and turn on the device.2. Place the seal roll, along with its holder, on the devicelocating the ends of the Axle in either Seal Roll Support 1or 2. The orientation of the seal roll should be as indicatedby the purple arrow.Seal Roll Support 1(seal roll with large diameter)Seal Roll Support 2(seal roll with small diameter)3. Perform the seal roll loading procedure (Please referto the a4S Operational Manual, section 2.4 Seal RollLoading Procedure).4. Perform the fine adjustment of the seal position (Pleaserefer to the a4S Operational Manual, section 2.5 FineAdjustment of the Seal Position).5. Adjust sealing temperature and time settings (Please seereverse page).6. Place the plate to be sealed on the plate carrier, usingan appropriate adaptor if necessary (Please see sectionPlate Adaptors).7. The Seal icon will remain grey while the unit is heatingor cooling. Once the set temperature is reached, the iconwill turn green.8. Sealing can then commence by touching SealPlate AdaptorsPlate Type / Plate Height Adaptor / Side of adaptor to use96well PCR plates011614.4 mm012026.54 mm013641.20 mm096016.1 mm038410.6 mmAdaptor BSide with 96 holes384well PCR plates011614.4 mm012026.54 mm013641.20 mm096016.1 mm038410.6 mmAdaptor BSide with 384 holes1536well plates,standard height plates011614.4 mm012026.54 mm013641.20 mm096016.1 mm038410.6 mm4mm ‒ 20mmAdaptor BSide with 384 holesMid-height plates011614.4 mm012026.54 mm013641.20 mm096016.1 mm038414mm ‒ 33mmAdaptor ADeep well plates011614.4 mm012026.54 mm013641.20 mm096016.1 mm038434mm ‒ 53mmNo adaptor needed |
Related manuals for 4titude a4S
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved